FAQ02826 of General Purpose Relays FAQ

FAQ No. FAQ02826

Primary Contents

Question

Which Sockets and Hold-down Clips are for MY General-purpose Relays?

Answer



Refer to the following table.

Connecting Sockets/Hold-down Clips Reference Table

TypeFront-mounting Socket
DIN track or screw mountingScrew mounting only
Without terminal coverWith terminal coverWithout terminal cover
Size of screw terminals: M3Size of screw terminals: M3.5
MY2
MY2N
MY2-D
MY2N-D2
MY2-CR *3
MY2N-CR *3
PYF08A
(PYC-A1)
PYF08A-E
(PYC-A1)
PYF08M
(PYC-P)
MY3
MY3N
MY3-D
MY3N-D2
PYF11A
(PYC-A1)
------
MY4
MY4N
MY4-D
MY4N-D2
MY4-CR *3
MY4N-CR *3
Size of screw terminals: M3---
PYF14A (PYC-A1)PYF14A-E
(PYC-A1)
Size of screw terminals: M3.5
PYF14T (PYC-A1)
TypeBack-mounting Socket
Soider terminalsWire-wrap terminalsPCB
terminals
Without clipWith clipWithout clipWith clip
Size of screw
terminals: M3.5
Terminal length:
25 mm
Terminal length:
20 mm
Terminal length:
25 mm
Terminal length:
20 mm
MY2
MY2N
MY2-D
MY2N-D2
MY2-CR *3
MY2N-CR *3
PY08
(PYC-P)
PY08-Y1PY08QN
(PYC-P)
PY08QN2
(PYC-P)
PY08QN-Y1PY08QN2-Y1PY08-02
(PYC-P)
MY3
MY3N
MY3-D
MY3N-D2
PY11
(PYC-P)
PY11-Y1PY11QN
(PYC-P)
PY11QN2
(PYC-P)
PY11QN-Y1PY11QN2-Y1PY11-02
(PYC-P)
MY4
MY4N
MY4-D
MY4N-D2
MY4-CR *3
MY4N-CR *3
PY14
(PYC-P)
PY14-Y1PY14QN
(PYC-P)
PY14QN2
(PYC-P)
PY14QN-Y1PY14QN2-Y1PY1-02
(PYC-P)

*1.Models indicated in parentheses are for the Hold-down Clips. Hold-down Clips are sold as two pieces per set, except for PCY-P, where only one Clip is included per set.

*2.PYF[]A-E models have terminal covers (finger protection). Round crimp terminals cannot be used for these models. Use forked crimp terminals.

*3.The Hold-down Clips are suitable for Relays that are smaller than 36 mm in height. Relays that are taller than 53 mm must be used with Y92H-3 or PYC-1 Back-mounting Sockets. (Y92H-3 is sold as two pieces per set, and PYC-1 as one piece per set.)

Note:Use the Surface-mounting Sockets (i.e., models with finger protection) with "-E" at the end of the model number. When using PF083A and PF113A, be sure not to exceed Sockets’ maximum carry current of 5 A. Using at a current exceeding 5 A may lead to burning. Round crimp terminals cannot be used for models with finger protection. Use forked crimp terminals.

Recommended Products

MY

Best-selling, general-purpose relays that can be selected based on operating environment and application

LY

Power-switching Compact General-purpose Relays

G3PE (Three-phase)

Compact, Slim-profile SSRs with Heat Sinks. Solid State Contactors for Three-phase Heaters Reduced Installation Work with DIN Track Mounting.

Other General Purpose Relays FAQ