Frequently asked questions and answers for Power Controllers - OMRON Industrial Automation
 Can three G3PX Power Controllers for single-phase applications be combined for control of three-phase loads?
Can three G3PX Power Controllers for single-phase applications be combined for control of three-phase loads?
               Which terminals should the G3PX Power Controller inputs be connected to?
Which terminals should the G3PX Power Controller inputs be connected to?
               What is a soft start?
What is a soft start?
               In PID control, what are the differences between ON/OFF time-sharing proportional control, cycle control, optimum cycle control, and phase control?
In PID control, what are the differences between ON/OFF time-sharing proportional control, cycle control, optimum cycle control, and phase control?
               How many G3PX Power Controllers can be connected to one Temperature Controller?
How many G3PX Power Controllers can be connected to one Temperature Controller?
               If 200V is applied to the AC100V terminal, what will happen?
If 200V is applied to the AC100V terminal, what will happen?
               What is a Power Regulator?
What is a Power Regulator?
               What is the gradient setting?
What is the gradient setting?
               What are the conditions for detecting disconnection for G3PX-2[][]EHN-CT Power Controllers that detect disconnection for multiple heaters?
What are the conditions for detecting disconnection for G3PX-2[][]EHN-CT Power Controllers that detect disconnection for multiple heaters?
               Why is the same power supply used for both the circuit power supply and the load power supply?
Why is the same power supply used for both the circuit power supply and the load power supply?
               Is it possible to use a three-phase power supply for single-phase G3PX Power Controllers?
Is it possible to use a three-phase power supply for single-phase G3PX Power Controllers?
               Why does the constant-current model sometimes have all indicators ON?
Why does the constant-current model sometimes have all indicators ON?
               What is a level indicator?
What is a level indicator?
               What is the minimum load current value that can be set?
What is the minimum load current value that can be set?
               How much heating value flows from the Electrical Regulator "G3PX"?
How much heating value flows from the Electrical Regulator "G3PX"?
               What is the constant-current function?
What is the constant-current function?
               What wiring should be used between a Temperature Controller and the G3PX Power Controllers?
What wiring should be used between a Temperature Controller and the G3PX Power Controllers?
               How should failure detection be wired?
How should failure detection be wired?
               What is phase control?
What is phase control?
               For the Electrical Regulator "G3PX" with the constant-current function, can protection be provided with the G3PX against load short circuiting?
For the Electrical Regulator "G3PX" with the constant-current function, can protection be provided with the G3PX against load short circuiting?