Primary Contents

Site Search Results

Site Search Product Search
Results 1051 - 1060 of 1600
K8DT-AW Single-phase Overcurrent/Undercurrent Rela...
... VAC 50/60Hz, 24 VDC K8DT-AW[][]A: 100 to 240 VAC 50/60Hz Power consumption 24 VAC/DC: 1.8 VA/1 W max. 100 to 240 VAC: 2.5 VA max. Rated insulation voltage 600 VAC Operating value setting ran...

https://www.ia.omron.com/products/family/3492/specification.html

K8DT-VS Single-phase Voltage Relay/Specifications ...
... VAC 50/60Hz, 24 VDC K8DT-VS[][]A: 100 to 240 VAC 50/60Hz Power consumption 24 VAC/DC: 1.8 VA/1 W max. 100 to 240 VAC: 2.5 VA max. Rated insulation voltage 600 VAC Operating value setting ran...

https://www.ia.omron.com/products/family/3493/specification.html

K8DT-VW Single-phase Overvoltage/Undervoltage Rela...
...AC 50/60 Hz, 24 VDC K8DT-VW[][]A: 100 to 240 VAC 50/60 Hz Power consumption 24 VAC/DC: 1.8 VA/1 W max. 100 to 240 VAC: 2.5 VA max. Rated insulation voltage 600 VAC Operating value setting ran...

https://www.ia.omron.com/products/family/3494/specification.html

K8DT-LS Conductive Level Controller/Specifications...
...0/60 Hz Voltage across electrodes 5 V p-p (Approx. 20 Hz) Power consumption 24 VAC/DC: 1.8 VA/1 W max. 100 to 240 VAC: 2.5 VA max. Rated insulation voltage 253 VAC Operating resistance 10 to ...

https://www.ia.omron.com/products/family/3495/specification.html

K8DT-TH Temperature Monitoring Relay/Specification...
...ange 85% to 110% of power supply voltage Power consumption 24 VAC or 24 VDC: 2.1 VA max. or 1.2 W max. 100 to 240 VAC: 3.1 VA max. Rated insulation voltage 253 VAC Sensor inputs K8DT-TH1 Ther...

https://www.ia.omron.com/products/family/3499/specification.html

G70V I/O Relay Terminal/Specifications | OMRON Ind...
...t 50 mA 6 A/point, 10 A/common (with -C4 installed) Maximum switching capacity --- 1,500 VA 180 W 500 VA 60 W Error rate (reference value) * 1 mA at 100 mVDC 10 mA at 5 VDC Electrica...

https://www.ia.omron.com/products/family/3509/specification.html

Hornet Parallel Robots/Lineup | OMRON Industrial A...
...079-000 T20 Adapter Cable, 3 m 10051-003 Camera Kit, Camera, GigE, POE, 720 x 540, 282.2 fps, B/W, M Series, 10 m camera cables included 31940-010 Kit, Camera, GigE, POE, 720 x 540, 282.2 fps...

https://www.ia.omron.com/products/family/3512/lineup.html

NX-RS[][][][] NX-series Load Cell Input Unit/Speci...
...D converter resolution 24 bits Warm-up period 30 minutes Conversion cycle 125 μs Dimensions 12 (W) × 100 (H) × 71 (D) Isolation method Between the input and the NX bus: Power = Transformer, S...

https://www.ia.omron.com/products/family/3538/specification.html

NX-HB NX-series Heater Burnout Detection Unit/Spec...
...terminals IOV: 0.1 A max. per terminal NX Unit power consumption • Connected to a CPU Unit 1.05 W max. • Connected to a Communications Coupler Unit 0.75 W max. Current consumption fr...

https://www.ia.omron.com/products/family/3539/specification.html

NX-ILM400 NX-series IO-Link Master Unit/Specificat...
...nal Block (16 terminals) I/O refreshing method Free-Run refreshing Dimensions 12 × 100 × 71 mm (W × H × D) Isolation method Photocoupler isolation Insulation resistance 20 MΩ min. at 100 VDC ...

https://www.ia.omron.com/products/family/3540/specification.html

Results 1051 - 1060 of 1600