Primary Contents

Site Search Results

Site Search Product Search IA Global Search
Results 1301 - 1310 of 1460
NX1P2 NX-series NX1P2 CPU Units/Specifications | O...
...ith 24 built-in I/O points, only one slot is provided. Keep the removed covers in a safe place. J Output indicator Shows the operation status of the built-in output. K Output terminal block T...

https://www.ia.omron.com/products/family/3650/specification.html

NX-TC NX-series Temperature Control Unit/Specifica...
...ulated variable -5 to +105% Sensor Input section Temperature sensor *1 • Thermocouple input: K, J, T, E, L, U, N, R, S, B, C/W, PL II • Platinum resistance thermometer input: Pt100 (three-wir...

https://www.ia.omron.com/products/family/3699/specification.html

R88M-1A[] / R88D-1SAN[]-ECT AC Servo System 1S-ser...
...time *9 ms 20 max. 20 max. 35 max. Backlash ° 1.2 max. 1.2 max. 1.0 max. Allowable braking work J 60 60 250 Allowable total work J 60,000 60,000 250,000 Allowable angular acceleratio...

https://www.ia.omron.com/products/family/3776/specification.html

NX-HTC NX-series Advanced Temperature Control Unit...
...igit Conversion time 50 ms per Unit Sensor Input section Sensor type *1 •Thermocouple input: K, J, T, E, L, U, N, R, S, B, C/W, PL II •Platinum resistance thermometer input: Pt100 (three-wire...

https://www.ia.omron.com/products/family/3902/specification.html

R88D-1SN[]-ECT-51 AC Servo System 1S-series with S...
...[] * The standard shaft type is a straight shaft. A model with a key and tap is indicated with “J” at [] of the Decelerator model number. e.g. R88G-HPG11B05100BJ For 2,000-r/min Servomotors S...

https://www.ia.omron.com/products/family/3923/lineup.html

R88D-1SN[]-ECT-51 AC Servo System 1S-series with S...
.... 15 max. 20 max. 20 max. Backlash ° 1.2 max. 1.2 max. 1.2 max. 1.2 max. Allowable braking work J 9 9 60 60 Allowable total work J 9,000 9,000 60,000 60,000 Allowable angular acceler...

https://www.ia.omron.com/products/family/3923/specification.html

PDFSensors Switches Safety Components Relays Control ...
...inal section by means of giving mating sections interlocking shapes. Δ××IP40 VD2S D3V-01 D2F VX J D2RV D2MQ D2MC D2D D3M SS SS-P OΔ O (except terminal sections) IP67 (except terminal sections...

https://www.ia.omron.com/data_pdf/guide/29/microswitch_tg_e_3_4.pdf

PDFSensors Switches Safety Components Relays Control ...
...E2) Voltage (E1) Resistor (R1) Resistor (R2) Digital Panel Indicator K3HB-XVD@@ K3HB-VLC@@ K3MA-J K3GN-N@@ K3HB-S Note.Select a CT with a rated load larger than 0.5 VA. Current Transformer (C...

https://www.ia.omron.com/data_pdf/guide/62/digital_panel_tg_e_3_3.pdf

PDFSensors Switches Safety Components Relays Control ...
...s output terminals (JIS definition). 60 50 40 30 20 10 500 0 1,000 R 1,500 Temperature (°C) T K J E Thermoelectromotive force (mV) Technical Explanation for Signal Converters 6 Sensors Switch...

https://www.ia.omron.com/data_pdf/guide/63/signals_tg_e_1_3.pdf

PDFSensors Switches Safety Components Relays Control ...
...balance rate = Negative phase component = + a2 + a Positive phase component + a + a2 a ( =− 1 + j ) 22 KA = 50 = 1.0, KB = 35 = 0.7, KC = 45 = 0.9 50 50 50 Ia . Ib . Ic . Ia . Ib . Ic . Ia . ...

https://www.ia.omron.com/data_pdf/guide/65/epsc_ps_tg_e_2_3_measuring_monitoringry_tg_e_1_2.pdf