Primary Contents

Site Search Results

Site Search Product Search IA Global Search
Results 1571 - 1580 of 4389
K3MA-L Temperature Meter/Lineup | OMRON Industrial...
...ial Automation Features Lineup Specifications Dimensions Catalog last update: February 13, 2014 Input type Supply voltage Output Model Platinum-resistance thermometer or thermocouple 100 to 2...

https://www.ia.omron.com/products/family/589/lineup.html

K3MA-F Frequency/Rate Meter/Lineup | OMRON Industr...
...Features Lineup Specifications Dimensions Catalog last update: February 13, 2014 List of Models Input type Supply voltage Output Model Rotary pulse 100 to 240 VAC None K3MA-F 100-240VAC 2 rel...

https://www.ia.omron.com/products/family/590/lineup.html

K3MA-F Frequency/Rate Meter/Specifications | OMRON...
...ng: EN61000-4-11: 0.5 cycle, 0, 180°, 100% (rated voltage) Weight Approx. 220 g Characteristics Input signal No-voltage contact (30 Hz max., ON/OFF pulse width: 15 ms min.) Voltage pulse (5 k...

https://www.ia.omron.com/products/family/590/specification.html

K2CU Heater Element Burnout Detector/Lineup | OMRO...
...cifications Dimensions Catalog last update: September 24, 2012 K2CU-F[][]A-[]GS Model with Gate Input Terminals Control supply voltage Operating current 4 to 10 A 8 to 20 A 16 to 40 A 32 to 8...

https://www.ia.omron.com/products/family/846/lineup.html

K2CU Heater Element Burnout Detector/Specification...
...% max. of operating current Operate time 0.5 s max. (when current changes from 150% to 0%) Gate input voltage range (for models with gate input terminals) 5 to 30 VDC --- Control out...

https://www.ia.omron.com/products/family/846/specification.html

LG2 Voltage Sensor/Specifications | OMRON Industri...
...o temperature change ±5% max. (within the range 20 °C +20/-30 °C) Operate time 0.5 s max. (when input changes from 0 V to 120% must-operate voltage) Release time 0.5 s max. (when ...

https://www.ia.omron.com/products/family/848/specification.html

G7TC I/O Relay Terminal/Lineup | OMRON Industrial ...
...pecify the rated voltage. I/O classification I/O points Internal I/O common Rated voltage Model Input 16 NPN (- common) 12 VDC G7TC-ID16 24 VDC 100 (110) VDC 100/(110) VAC G7TC-IA16 200/(220)...

https://www.ia.omron.com/products/family/859/lineup.html

G70D-SOC08 Relay Terminal/Specifications | OMRON I...
....0-mm double) Shock resistance Destruction 300 m/s 2 Malfunction 100 m/s 2 Noise immunity Power input (normal mode) 600 V for 10 min with a pulse width of 100 ns to 1 μs Power input ...

https://www.ia.omron.com/products/family/863/specification.html

G3S4 Terminal SSR/Dimensions | OMRON Industrial Au...
...) Terminal Arrangement/Internal Connections (Top View) Note: Make sure that the polarity of the input terminal is correct.          The polarity given inside parentheses ( ) is for G3S4-D and...

https://www.ia.omron.com/products/family/902/dimension.html

G3S4 Terminal SSR/Specifications | OMRON Industria...
...Index Features Lineup Specifications Dimensions Catalog last update: September 24, 2012 Ratings Input (per G3S Relay) Rated voltage Operating voltage Must operate level Must release voltage l...

https://www.ia.omron.com/products/family/902/specification.html