Safety Precautions of Solid-state Relays Cautions ...
...han the must release voltage of the SSR. Twisted-pair wires: For electromagnetic noise Shielded cable: For static noise A filter consisting of a combination of capacitor and resistor will eff...

https://www.ia.omron.com/product/cautions/18/safety_precautions.html

Safety Precautions of Timers Cautions for Timers |...
... the top and bottom sides. When using the US08, be sure to use 10.5-mm-dia. max. multiconductor cable or 3-mm-dia. max. insulated stranded wire for wiring. When the Y92F-40, Y92F-70, Y92F-71,...

https://www.ia.omron.com/product/cautions/19/safety_precautions.html

Safety Precautions of Power Supplies Cautions for ...
...l diagrams for each model for specific dimensions. Wiring Use caution when connecting the input cable to the Power Supply. The Power Supply Unit may be destroyed if the input cable i...

https://www.ia.omron.com/product/cautions/22/safety_precautions.html

Safety Precautions of Photomicro Sensors Cautions ...
...odels that begin with EE-SP), the design must take into account the effects of power source and cable length. Photomicrosensors with Modulated Light are more easily affected than Photomicrose...

https://www.ia.omron.com/product/cautions/24/safety_precautions.html

Safety Precautions of Limit Switches Cautions for ...
...etrate into the Switch through the conduit opening. Be sure to attach a connector suited to the cable thickness and tighten the connector securely to the rated torque. Do not impose shock or ...

https://www.ia.omron.com/product/cautions/30/safety_precautions.html

Safety Precautions of Rotary Encoders Cautions for...
...in the following graphs (theoretical value). E6B2-C E6C2-C[] E6C3-C[]H Wiring If connecting the cable after securing the Encoder, do not pull on the cable with a force of 29.4 N or g...

https://www.ia.omron.com/product/cautions/34/safety_precautions.html

Safety Precautions of Proximity Sensors Cautions f...
... (Model example: E2E-X[]D[]-U) Table 3: AC 2-wire Table 4: DC 3-wire NPN Table 5: DC 3-wire PNP Cable The insulated part of the cable terminal is used for our internal characteristic...

https://www.ia.omron.com/product/cautions/41/safety_precautions.html

Safety Precautions of Photoelectric Sensors Cautio...
...oise filter (e.g.,ferrite core or insulated transformer), or varistor in the power line. Wiring Cable The insulated part of the cable terminal is used for our internal characteristic...

https://www.ia.omron.com/product/cautions/43/safety_precautions.html

Safety Precautions of Axial Fans Cautions for Axia...
...ct label. 7. When using the following model, ensure EMC conformity by using a power supply line cable no longer than 30 m. In addition, do not connect to a DC distribution network. Applicable...

https://www.ia.omron.com/product/cautions/45/safety_precautions.html

Safety Precautions of Digital Panel Indicators Cau...
...rom power lines carrying high voltages or currents. Do not wire in parallel with or in the same cable as power lines. Other measures for reducing noise include running lines along separate du...