FAQ00705 for Digital Panel Indicators | OMRON Indu...- ...measuring accuracy for K3NR operating mode 1 (rotational/circumferential speed) is ±0.006% rdg ±1 digit. If the variation of input pulses is not considered, the error depends on the...
https://www.ia.omron.com/support/faq/answer/62/faq00705/
K3HB-X Process Indicator/Specifications | OMRON In...- ...us overload (30 s) K3HB-XVD DC voltage (CAT II) A ±199.99 V -19.999 to 21.999 V 10 MΩ min. ±0.1%rdg ± 1 digit max. ±400 V B ±19.999 V -19.999 to 21.999 V 1 MΩ min. ±200 V C ±1.9999 V -19.999 ...
https://www.ia.omron.com/products/family/1535/specification.html
S8AS Smart Power Supply/Specifications | OMRON Ind...- ...max. Display functions Output voltage display Display range:17.0 to 30.0 V Display accuracy: 2% rdg ±1 digit max. Output current display Branch output display range: 0.0 to 4.0 A Peak output ...
https://www.ia.omron.com/products/family/1948/specification.html
ES1-N Infrared Thermosensor/Specifications | OMRON...- ...mption 30 mA max. (24 VDC) Cable length 2 m ±5 cm Measurement accuracy USB output • Within ±(-8%rdg+1)°C (Measurement temperature: -50 to 0°C) • Within ±1°C (0 to 200°C) • Within ±0.5%...
https://www.ia.omron.com/products/family/3676/specification.html
K7GE-MG Insulation Resistance Monitoring Device/Sp...- ...fications Measurement range 0.1 to 99.9 MΩ (0.0 MΩ for less than 0.1 MΩ) Measuring accuracy ±5% rdg. ±1 digit (at ambient temperature -10 to 55°C and ambient humidity 25% to 65%) Megger volta...
https://www.ia.omron.com/products/family/3811/specification.html
K7TM Heater Condition Monitoring Device/Specificat...- ... Variations in CTs are not included. Repeat accuracy of resistance value (reference value): ±1% rdg ±1 digit Conditions: • When sine waves are input continuously • Variations in CTs are not i...
https://www.ia.omron.com/products/family/3855/specification.html
K7DD Advanced Motor Condition Monitoring Device/Sp...- ... (Ambient temperature: 10 to 30°C) Current Absolute accuracy: 0.5%FS±1digit Repeat accuracy: ±1%rdg±1digit Not including accuracy variation of CTs The power frequency must be within the rated...
https://www.ia.omron.com/products/family/3893/specification.html
S8AS2 Smart Power Supply (240/480 W)/Specification...- ...ess Display functions Output voltage display Display range: 16.3 to 32.0 V Display accuracy: 2% rdg ±1 digit max. Output current display Branch output current Display range: 0.0 to 20.0 A Bra...
https://www.ia.omron.com/products/family/3956/specification.html
K6CM Motor Condition Monitoring Device/Specificati...- ...Ω, Leakage current: 0.0 mA to 200.0 mA Measurement absolute accuracy Insulation resistance ±35% rdg±2 digit (when the insulation resistance is 0.2 MΩ max.), when a 200-V/7.5-kW max. motor is ...
https://www.ia.omron.com/products/family/3686/specification.html
S8NR-S / S8R-BB Environment-resistant IP67 Power S...- ...it) Display functions Output voltage display Display range: 16.3 to 30.0 V Display accuracy: 2% rdg ±1 digit max. Output current display Branch output current display range: 0.0 to 4.0 A (M12...