| Site Search | Product Search | IA Global Search |
... ±10%, ripple (p-p): 10% max. Current consumption 40 mA max. Control output NPN open collector: Load power supply voltage: 5 to 24 VDC Load current: 100 mA max. OFF current: 0.5 mA m...
https://www.ia.omron.com/products/family/444/specification.html
...Sensor, Cylinder type (with screw), Sensing distance: 10 mm, Shielded, DC 3-wire, NPN collector load built-in output, NO, Different frequency, Pre-wired model, Standard PVC cable (oil resista...
...-p): 10% max. Current consumption --- 15 mA max. Leakage current 0.8 mA max. --- Control output Load current 3 to 100 mA max. NPN open-collector output/ PNP open-collector output 100 mA max. ...
https://www.ia.omron.com/products/family/454/specification.html
... to 24 VDC (10 to 30 VDC), ripple (p-p): 10% max. Current consumption 20 mA max. Control output Load current NPN open-collector output, 100 mA max. (at 30 VDC) Residual voltage 2 V max. ...
https://www.ia.omron.com/products/family/457/specification.html
...F Models: 15 mA max. Leakage current Y Models: 2.2 mA max. (Refer to Datasheet.) Control output Load current E and F Models: 200 mA max.*2, Y Models: 10 to 200 mA Residual voltage E and F Mod...
https://www.ia.omron.com/products/family/471/specification.html
... (10 to 30 VDC), ripple (p-p): 10% max. Current consumption 10 mA max. at 24 VDC Control output Load current NPN open collector, 100 mA max. (at 30 VDC) Residual voltage 1.5 V max. (...
https://www.ia.omron.com/products/family/472/specification.html
...(p-p) 10% max. 100 to 220 VAC (90 to 250 VAC), 50/60 Hz Current consumption 10 mA max. (with no load) --- Leakage current --- Refer to Datasheet. Control output Switching capacity NPN open co...
https://www.ia.omron.com/products/family/480/specification.html
...for 1 min between terminals and case Life expectancy 50,000,000 times min. with 0.1-A resistive load at 24 VDC Vibration resistance Destruction: 10 to 55 Hz, 1.5-mm double amplitude for 2 hou...
https://www.ia.omron.com/products/family/481/specification.html
...*3 100 kHz 50 kHz 100 kHz Rise and fall times of output 1 μs max. (Control output voltage: 5 V, Load resistance: 1 kΩ, Cable length: 2 m max.) 1 μs max. (Cable length: 2 m max., Sink current:...
https://www.ia.omron.com/products/family/487/specification.html
...n A and B (1/4 T ± 1/8 T) Rise and fall times of output 1 μs max. (Control output voltage: 5 V, Load resistance: 1 kΩ, Cable length: 2 m) 1 μs max. (Cable length: 2 m, Load current: ...
https://www.ia.omron.com/products/family/488/specification.html
... length: 2 m, Output current: 30 mA) 1 μs max. (Cable length: 2 m, Control output voltage: 5 V, Load resistance: 1 kΩ) Starting torque 10 mNm max. at room temperature, 15 mNm max. at low temp...
https://www.ia.omron.com/products/family/490/specification.html
...n A and B (1/4 T ± 1/8 T) Rise and fall times of output 1 μs max. (Control output voltage: 5 V, Load resistance: 1 kΩ, Output cable: 500 mm) 1 μs max. (Io = -10 mA, Is = 10 mA, Output cable: ...
https://www.ia.omron.com/products/family/491/specification.html
...om the end of the shaft) Rise and fall times of output 1 μs max. (Control output voltage: 16 V, Load resistance: 1 kΩ, Output cable: 2 m max.) Starting torque 0.98 mN·m max. Moment of inertia...
https://www.ia.omron.com/products/family/494/specification.html
...A max. at 24 VDC E4E2-TS50RC1 Receiver: 15 mA max. at 24 VDC Control output NPN open collector, Load voltage: 26.4 VDC max., Load current: 100 mA max. (Residual voltage: 1 V max.) In...
https://www.ia.omron.com/products/family/504/specification.html
...perating voltage range 85% to 110% of the rated supply voltage Power consumption (under maximum load) 6 VA max. 4.5 VA max. (24 VAC) 4.5 W max. (24 VDC) Insulation resistance 20 MΩ min. (at 5...
https://www.ia.omron.com/products/family/588/specification.html
...perating voltage range 85% to 110% of the rated supply voltage Power consumption (under maximum load) 6 VA max. 4.5 VA max. (24 VAC) 4.5 W max. (24 VDC) External power supply 12 VDC (±10%), 0...
https://www.ia.omron.com/products/family/590/specification.html
... Specifications Dimensions Catalog last update: January 22, 2014 Ratings Model Detected voltage Load Setting range Control output Rated voltage Power/VA consumption Must-operate (SET) voltage...
https://www.ia.omron.com/products/family/848/specification.html
... 5. The rated current includes the terminal’s LED current. Contact Ratings (per G6D Relay) Load Resistive load (cosφ = 1) Rated load 5 A at 250 V AC, 5 A at 30 V DC Rat...
https://www.ia.omron.com/products/family/863/specification.html
... Ratings Classification G6B-4BND (standard), G6B-47BND (long-life) G6B-48BND (high-reliability) Load Resistive load (cosφ = 1) Inductive load (cosφ = 0.4, L/R = 7 ms) Resist...
https://www.ia.omron.com/products/family/901/specification.html
...3SD-Z01P-PD Note: 1. The polarity given inside parentheses ( ) is for DC loads. 2. The load can be connected to ether the positive or negative SSR output terminal. Relay Removal Tool...