EE-SY671 / 672 Reflective Photomicrosensor with Se...

... ±10%, ripple (p-p): 10% max. Current consumption 40 mA max. Control output NPN open collector: Load power supply voltage: 5 to 24 VDC Load current: 100 mA max. OFF current: 0.5 mA m...

https://www.ia.omron.com/products/family/444/specification.html

E2E DC 2-Wire (PUR Cable/Self-diagnosis Output), A...

...Sensor, Cylinder type (with screw), Sensing distance: 10 mm, Shielded, DC 3-wire, NPN collector load built-in output, NO, Different frequency, Pre-wired model, Standard PVC cable (oil resista...

https://www.ia.omron.com/products/family/449/itemlist/

E2EZ Chip-immune Inductive Proximity Sensor/Specif...

...-p): 10% max. Current consumption --- 15 mA max. Leakage current 0.8 mA max. --- Control output Load current 3 to 100 mA max. NPN open-collector output/ PNP open-collector output 100 mA max. ...

https://www.ia.omron.com/products/family/454/specification.html

E2EY Aluminum-detecting Proximity Sensor/Specifica...

... to 24 VDC (10 to 30 VDC), ripple (p-p): 10% max. Current consumption 20 mA max. Control output Load current NPN open-collector output, 100 mA max. (at 30 VDC) Residual voltage 2 V max. ...

https://www.ia.omron.com/products/family/457/specification.html

E2K-X Cylindrical Proximity Sensor/Specifications ...

...F Models: 15 mA max. Leakage current Y Models: 2.2 mA max. (Refer to Datasheet.) Control output Load current E and F Models: 200 mA max.*2, Y Models: 10 to 200 mA Residual voltage E and F Mod...

https://www.ia.omron.com/products/family/471/specification.html

E2K-F Flat Proximity Sensor/Specifications | OMRON...

... (10 to 30 VDC), ripple (p-p): 10% max. Current consumption 10 mA max. at 24 VDC Control output Load current NPN open collector, 100 mA max. (at 30 VDC) Residual voltage 1.5 V max. (...

https://www.ia.omron.com/products/family/472/specification.html

TL-LP / LY Long-distance Proximity Sensor/Specific...

...(p-p) 10% max. 100 to 220 VAC (90 to 250 VAC), 50/60 Hz Current consumption 10 mA max. (with no load) --- Leakage current --- Refer to Datasheet. Control output Switching capacity NPN open co...

https://www.ia.omron.com/products/family/480/specification.html

GLS Magnetic Proximity Sensor/Specifications | OMR...

...for 1 min between terminals and case Life expectancy 50,000,000 times min. with 0.1-A resistive load at 24 VDC Vibration resistance Destruction: 10 to 55 Hz, 1.5-mm double amplitude for 2 hou...

https://www.ia.omron.com/products/family/481/specification.html

E6B2-C Incremental 40-mm-dia. Rotary Encoder/Speci...

...*3 100 kHz 50 kHz 100 kHz Rise and fall times of output 1 μs max. (Control output voltage: 5 V, Load resistance: 1 kΩ, Cable length: 2 m max.) 1 μs max. (Cable length: 2 m max., Sink current:...

https://www.ia.omron.com/products/family/487/specification.html

E6C2-C Slim Incremental 50-mm-dia. Rotary Encoder/...

...n A and B (1/4 T ± 1/8 T) Rise and fall times of output 1 μs max. (Control output voltage: 5 V, Load resistance: 1 kΩ, Cable length: 2 m) 1 μs max. (Cable length: 2 m, Load current: ...

https://www.ia.omron.com/products/family/488/specification.html

E6F-C Incremental 60-mm-dia. Rotary Encoder/Specif...

... length: 2 m, Output current: 30 mA) 1 μs max. (Cable length: 2 m, Control output voltage: 5 V, Load resistance: 1 kΩ) Starting torque 10 mNm max. at room temperature, 15 mNm max. at low temp...

https://www.ia.omron.com/products/family/490/specification.html

E6H-C Hollow-shaft Encoder with Diameter of 40 mm/...

...n A and B (1/4 T ± 1/8 T) Rise and fall times of output 1 μs max. (Control output voltage: 5 V, Load resistance: 1 kΩ, Output cable: 500 mm) 1 μs max. (Io = -10 mA, Is = 10 mA, Output cable: ...

https://www.ia.omron.com/products/family/491/specification.html

E6CP-A Low-cost Encoder with Diameter of 50 mm/Spe...

...om the end of the shaft) Rise and fall times of output 1 μs max. (Control output voltage: 16 V, Load resistance: 1 kΩ, Output cable: 2 m max.) Starting torque 0.98 mN·m max. Moment of inertia...

https://www.ia.omron.com/products/family/494/specification.html

E4E2 Compact Ultrasonic Sensor/Specifications | OM...

...A max. at 24 VDC E4E2-TS50RC1 Receiver: 15 mA max. at 24 VDC Control output NPN open collector, Load voltage: 26.4 VDC max., Load current: 100 mA max. (Residual voltage: 1 V max.) In...

https://www.ia.omron.com/products/family/504/specification.html

K3MA-J Process Meter/Specifications | OMRON Indust...

...perating voltage range 85% to 110% of the rated supply voltage Power consumption (under maximum load) 6 VA max. 4.5 VA max. (24 VAC) 4.5 W max. (24 VDC) Insulation resistance 20 MΩ min. (at 5...

https://www.ia.omron.com/products/family/588/specification.html

K3MA-F Frequency/Rate Meter/Specifications | OMRON...

...perating voltage range 85% to 110% of the rated supply voltage Power consumption (under maximum load) 6 VA max. 4.5 VA max. (24 VAC) 4.5 W max. (24 VDC) External power supply 12 VDC (±10%), 0...

https://www.ia.omron.com/products/family/590/specification.html

LG2 Voltage Sensor/Specifications | OMRON Industri...

... Specifications Dimensions Catalog last update: January 22, 2014 Ratings Model Detected voltage Load Setting range Control output Rated voltage Power/VA consumption Must-operate (SET) voltage...

https://www.ia.omron.com/products/family/848/specification.html

G70D-SOC08 Relay Terminal/Specifications | OMRON I...

...      5. The rated current includes the terminal’s LED current. Contact Ratings (per G6D Relay) Load Resistive load (cosφ = 1) Rated load 5 A at 250 V AC, 5 A at 30 V DC Rat...

https://www.ia.omron.com/products/family/863/specification.html

G6B-4[][]ND Terminal Relay/Specifications | OMRON ...

... Ratings Classification G6B-4BND (standard), G6B-47BND (long-life) G6B-48BND (high-reliability) Load Resistive load (cosφ = 1) Inductive load (cosφ = 0.4, L/R = 7 ms) Resist...

https://www.ia.omron.com/products/family/901/specification.html

G3S4 Terminal SSR/Dimensions | OMRON Industrial Au...

...3SD-Z01P-PD Note: 1. The polarity given inside parentheses ( ) is for DC loads.          2. The load can be connected to ether the positive or negative SSR output terminal. Relay Removal Tool...

https://www.ia.omron.com/products/family/902/dimension.html