| IAグローバル検索 |
... No. 01h 0 1 Test data Command code 1 Data 1 0 1 Data 2 2 3 Data 3 4 5 FCS Data 4 6 7 8 0 CR 8 0Dh Response SOH Node No. Response code 01h 0 0 1 0 Test data Data 1 1 Data 2 2 3 Data 3 4 5 FCS...
https://www.omron-ap.co.nz/data_pdf/mnu/z218-e1-01a_v640-ham12_hs62.pdf
...and * Each character is output as an ASCII code (except for FLOWDATA response). M E A S U R E O CR Delimiter Space The format of returned values changes depending on the command. For the desc...
...Up to two Extension Cables can be daisy-chained.) - Extension cable for a long distance ZS-XC_ _CR: within 27 m (including Sensor Head. Digital equalizer ZS-XEQ and the Digital equalizer conn...
https://www.omron-ap.co.nz/data_pdf/mnu/z236-e1-08_zs-hl.pdf
... the USB Port The distance level and Antenna channel are output from the USB port. DL 06 1 0 * [CR] Resend Flag (Always "0".) Antenna channel ("1": channel 1, "2": channel 2) Distance level (...
https://www.omron-ap.co.nz/data_pdf/mnu/z249-e1-12_v680-ca5d0_-v2.pdf
...015Hex.> 1.Reading data from the RF tag addresses 0010Hex to 0015Hex. Command : RDSTH100100006*[CR] Reseponse : RD0010001122334455*[CR] ...
https://www.omron-ap.co.nz/data_pdf/mnu/z262-e1-09a_v680.pdf
... PRTY (parity) NONE (none), ODD (odd), EVEN (even) (default value: NONE) HD.FT ST.ET (STX+ETX), CR, CR.LF (CR+LF) (header/footer selection) (default value: CR) 1 Se...
https://www.omron-ap.co.nz/data_pdf/mnu/z263-e1-05_zx-gt.pdf
...ands W T A 1 byte 1 0 Command code ASCII Processing setting area number setting 0 1 0 O M R O N CR Write data Start address Terminator V680 Commands W T S T A 1 0 ASCII Processing Command cod...
https://www.omron-ap.co.nz/data_pdf/mnu/z272-e1-09_v680-chud_ch1d.pdf
...D E F 90 0 1 2 3 4 5 6 7 NUL SOH STX ETX EOT ENQ ACK BEL BS HT LF VT FF CR SO SI DLE DC1 DC2 DC3 DC4 NAK SYN ETB CAN EM SUB ESC FS GS RS US SPACE ! ‘‘ # $ % & ‘ ( ) * + , . / 0 1 2 3 4 5 6 7 ...
...ON, ODD, EVEN STOP BIT 1BIT 1BIT, 2BIT BAUD RATE 38400 9600A19200A38400A57600 A115200 DELIMITER CR+LF CR, LF, CR+LF PASSWORD ON/OFF OFF (Displayed only when password is set ...
...d a maximum of 27 m. Cable for Sensor: 0.5 m, 2 m (flexible cable) Extension cable (*1) ZG2-XC__CR: (3 m, 8 m, 15 m, 25 m) (flexible cable) *1 You cannot connect two or more extension cables....
... (default value: 1BIT) BAUDRAT 9600, 19200, 38400, 57600, 115200 (default value: 38400) DELIMIT CR, LF, CR+LF (default value: CR) NODE 0 to 16 (default value: 0) Note This "...
https://www.omron-ap.co.nz/data_pdf/mnu/z289-e1-03_zg2-dsu.pdf
...nications Test • 1:1 Protocol Command Test data Command code 1 Data 1 0 1 Data 2 2 3 Data 3 4 5 CR Data 4 6 7 8 0Dh Response Test data Response code 0 0 Data 1 1 Data 2 2 3 Data 3 4 5 ...
https://www.omron-ap.co.nz/data_pdf/mnu/z307-e1-02_v640-ham11-v3.pdf
...Unit using the data 12345678. Command Test data Command code 1 Data 1 0 1 Data 2 2 3 Data 3 4 5 CR Data 4 6 7 8 0Dh Response Test data Response code 0 0 Data 1 1 Data 2 2 3 Data 3 4 5 ...
https://www.omron-ap.co.nz/data_pdf/mnu/z308-e1-02_v640-ham11-etn.pdf
...lon Decimal symbol None, point (default), or comma Record separator None, comma, tab, space, or CR or CF+LF (default) Use the following menu command to change the output CSV file format. (Set...
https://www.omron-ap.co.nz/data_pdf/mnu/z316-e1-02_fq-cr.pdf
...Y This is the Y coordinate of the position −99999.9999 to 99999.9999 where the model was found. CR Correlation This value indicates how similar the image is to the image registered as referen...
https://www.omron-ap.co.nz/data_pdf/mnu/z329-e1-02_fq-cr1_____-m.pdf
... setting) Stop bit 1 bit (Factory default setting) Header None (Factory default setting) Footer CR (Factory default setting) Reading valid time Trigger + 2 sec. (Factory default setting) Proc...
https://www.omron-ap.co.nz/data_pdf/mnu/z333-e1-04_v400-r2.pdf
...odd, or even * 77 bits or 8 bits 1sbit* or 2 bits None*, 02
https://www.omron-ap.co.nz/data_pdf/mnu/z334-e1-03_v500-r2.pdf
... the Images That Were Taken -180 to 180 FQ2-S/CH User’s Manual Expression text string Data name CR Correlation Description Data range This is the correlation. 0 to 100 • Measurement Data That...
https://www.omron-ap.co.nz/data_pdf/mnu/z337-e1-12_fq2-s_ch.pdf
... Conversion The converted codes are outputted for the following character codes. Character code CR LF DEL FF 24 Before conversion After conversion &h0D &h0A &h7F &hFF Control Methods Using an...
https://www.omron-ap.co.nz/data_pdf/mnu/z338-e1-05_fq2-s_ch.pdf
...data 12345678. • 1:1 Protocol Command Test data Command code 1 Data 1 0 1 Data 2 2 3 Data 3 4 5 CR Data 4 6 7 8 0Dh Response Test data Response code 0 0 Data 1 1 Data 2 2 3 Data 3 4 5 ...
https://www.omron-ap.co.nz/data_pdf/mnu/z360-e1-05_v640-ham11-v4_-l-v2.pdf