G2R-1-SN AC200/(220) | OMRON Industrial Automation
...10 A Maximum switching power 2500 VA (Resistive load) 1875 VA (Inductive load (cosφ = 0.4)) 300 W (Resistive load) 150 W (Inductive load (L/R = 7 ms)) Contact form SPDT Contact metho...

https://www.ia.omron.com/product/item/5673/

G2R-1-SN DC100 | OMRON Industrial Automation
... Release voltage (Reset voltage) 15 % min. Maximum voltage 110 % Power consumption Approx. 0.53 W Contact Contact rated load 250 VAC 10 A (Resistive load) 250 VAC 7.5 A (Inductive load (cosφ ...

https://www.ia.omron.com/product/item/5676/

G2R-1-SN DC12 | OMRON Industrial Automation
... Release voltage (Reset voltage) 15 % min. Maximum voltage 110 % Power consumption Approx. 0.53 W Contact Contact rated load 250 VAC 10 A (Resistive load) 250 VAC 7.5 A (Inductive load (cosφ ...

https://www.ia.omron.com/product/item/5678/

G2R-1-SN DC24 | OMRON Industrial Automation
... Release voltage (Reset voltage) 15 % min. Maximum voltage 110 % Power consumption Approx. 0.53 W Contact Contact rated load 250 VAC 10 A (Resistive load) 250 VAC 7.5 A (Inductive load (cosφ ...

https://www.ia.omron.com/product/item/5679/

G7J-2A2B-P DC100 | OMRON Industrial Automation
...ax. Release voltage (Reset voltage) 10 % min. Maximum voltage 110 % Power consumption Approx. 2 W Contact Contact rated load 220 VAC 25 A (NO contact: Resistive load) 220 VAC 25 A (NO contact...

https://www.ia.omron.com/product/item/6092/

G7J-2A2B-P DC48 | OMRON Industrial Automation
...ax. Release voltage (Reset voltage) 10 % min. Maximum voltage 110 % Power consumption Approx. 2 W Contact Contact rated load 220 VAC 25 A (NO contact: Resistive load) 220 VAC 25 A (NO contact...

https://www.ia.omron.com/product/item/6095/

G7J-3A1B-P DC100 | OMRON Industrial Automation
...ax. Release voltage (Reset voltage) 10 % min. Maximum voltage 110 % Power consumption Approx. 2 W Contact Contact rated load 220 VAC 25 A (NO contact: Resistive load) 220 VAC 25 A (NO contact...

https://www.ia.omron.com/product/item/6119/

G7J-3A1B-PZ AC200/240 | OMRON Industrial Automatio...
...ontact: Inductive load (cosφ = 0.4)) 220 VA (Twin contacts (NC): Resistive load (cos φ= 1)) 750 W (NO contact: Resistive load) 240 W (NC contact: Resistive load) Contact form 3PST-NO...

https://www.ia.omron.com/product/item/6123/

G7J-3A1B-PZ DC12 | OMRON Industrial Automation
...ax. Release voltage (Reset voltage) 10 % min. Maximum voltage 110 % Power consumption Approx. 2 W Contact Contact rated load 220 VAC 25 A (NO contact: Resistive load) 220 VAC 25 A (NO contact...

https://www.ia.omron.com/product/item/6124/

H3Y-2 DC12 120S | OMRON Industrial Automation
...ble voltage variable range 90 to 110% of the power supply voltage Power consumption Approx. 0.9 W (at 12 VDC) Reset voltage 10% min, of rated supply voltage Number of time ranges 1 Operation ...

https://www.ia.omron.com/product/item/61811/