| Site Search | Product Search | IA Global Search |
... modes --- Input mode: Not 2-input independent measurement: Upper and lower limits, area, upper limit, lower limit. 2-input independent measurement: Upper limit, lower ...
https://www.ia.omron.com/products/family/1931/specification.html
...icker OFF start Flicker ON start Pin type 11-pin 8-pin 11-pin 8-pin Operating/Reset method Time-limit operation/Time-limit reset or self-reset Output type Relay output (DPDT) Mountin...
https://www.ia.omron.com/products/family/194/specification.html
...o 5 V, 0 to 10 V) Detection level Temperature input: If the temperature exceeds the high or low limit of the sensor range by 20°C or 20°F. +1 to +5 V: input signal ...
https://www.ia.omron.com/products/family/1988/specification.html
... P). H3DS-G General Item H3DS-G Operating mode Star-delta operation Operating/Reset method Time-limit operation/Self-reset External connections Screw terminal, Screw-Less Clamp Terminal block...
https://www.ia.omron.com/products/family/201/specification.html
...setting 0.0% to 100% Base-up value 0.0% to 100% (Default: 0.0%) Upper/lower limits Output upper limit: 0.0% to 100% (Default: 100%) Output lower limit: 0.0% to 100% (Default: 0.0%) D...
https://www.ia.omron.com/products/family/2011/specification.html
...present command position, but also the present position from the feedback pulse counter. Torque limit output An output signal is available for operating the torque limit switch input...
https://www.ia.omron.com/products/family/2051/specification.html
...Transmission distance 100 m (distance between hub and node) No. of cascade-connectable Units No limit when a switching hub is used. DeviceNet Communications Specifications Communications prot...
https://www.ia.omron.com/products/family/2621/specification.html
...smission distance 100 m (distance between hub and node) Number of cascade- connectable units No limit when a switching hub is used. Weight 23 g max. Dimensions 36.4 (W) x 36.4 (H) x 28.2 (D) ...
https://www.ia.omron.com/products/family/2937/specification.html
...ax. *3 At 440 VAC: 34 VA max. H3DK-GA At 12 VDC: 0.9 W max. Control output Contact output (Time-limit output: relay, Star output: SPDT, Delta output: SPDT): 5 A at 250 VAC with resistive load...
https://www.ia.omron.com/products/family/2986/specification.html
...ative alarm value (X) Deviation alarm/ absolute value alarm 0 No alarm Output OFF 1 Upper/lower limit Always ON Deviation alarm 2 Upper limit Deviation alarm 3 Lower limit D...
https://www.ia.omron.com/products/family/3024/specification.html
...ning, PV input shift, run/stop, protection functions, extraction of square root, MV change rate limit, logic operations, temperature status display, simple programming, moving average of inpu...
https://www.ia.omron.com/products/family/3101/specification.html
...ning, PV input shift, run/stop, protection functions, extraction of square root, MV change rate limit, logic operations, temperature status display, simple programming, moving average of inpu...
https://www.ia.omron.com/products/family/3102/specification.html
...nous torque mode Profile position mode Homing mode Touch probe function (Latch function) Torque limit function Linear Motor General Specifications Iron-core Linear Motors Item Description Ope...
https://www.ia.omron.com/products/family/3145/specification.html
...with sheath) Thermal contact Non-grounded type Temperature range 0°C to permissible temperature limit Lead wire Vinyl-covered with external dimensions of 2.4 x 4.1 7/0.3 -20°C to 70°C Permiss...
https://www.ia.omron.com/products/family/3152/specification.html
...ning, PV input shift, run/stop, protection functions, extraction of square root, MV change rate limit, logic operations, temperature status display, simple programming, moving average of inpu...
https://www.ia.omron.com/products/family/3157/specification.html
...bar Limited (RSS Limited), GS1-Databar Expanded (RSSExpanded) Number of reading digits No upper limit (depends on bar width and reading distance) Reading performance * Minimum resolution Bar ...
https://www.ia.omron.com/products/family/3173/specification.html
...F417, AztecCode, MaxiCode, Codablock-F Reading performance *2 Number of reading digits No upper limit (depends on bar width and reading distance) Light source Two red LEDs (wave length: 617 n...
https://www.ia.omron.com/products/family/3174/specification.html
...of D4C Related Contents Common Cautions Technical Guide Models with Standards Certification FAQ Limit Switches Item A to Z Index Glossary of Industrial Automation Features Lineup Specificatio...
...of D4C Related Contents Common Cautions Technical Guide Models with Standards Certification FAQ Limit Switches Item A to Z Index Glossary of Industrial Automation Features Lineup Specificatio...
https://www.ia.omron.com/products/family/324/specification.html
...ndicators Power (PWR): Green LED, Relay output (ALM): Red LED Other functions Alarm Mode (upper limit/lower limit), non-fail safe/fail safe selection, output latch, setting protectio...
https://www.ia.omron.com/products/family/3241/specification.html