Primary Contents

IA Global Search Results

Select Country in

Site Search Product Search IA Global Search
Results 5641 - 5660 of 46263
NX-ECT101 NX-series EtherCAT® Slave Unit/Specifica...

...Insulation resistance 20 MΩ min. between isolated circuits (at 100 VDC) Dielectric strength 510 VAC between isolated circuits for 1 minute at a leakage current of 5 mA max. I/O power supply m...

https://www.ia.omron.com/products/family/3862/specification.html

G9SA Safety Relay Unit/Lineup | OMRON Industrial A...

...umber of input channels Rated voltage Model 3PST-NO SPST-NC 1 channel or 2 channels possible 24 VAC/VDC G9SA-301 100 to 240 VAC 5PST-NO 24 VAC/VDC G9SA-501 100 to 240 ...

https://www.ia.omron.com/products/family/389/lineup.html

G9SA Safety Relay Unit/Specifications | OMRON Indu...

...16, 2022 Ratings Power Input Model G9SA-301/TH301 G9SA-501 G9SA-321-T[] Power supply voltage 24 VAC/VDC: 24 VAC, 50/60 Hz, or 24 VDC 100 to 240 VAC: 100 to 240 VAC,...

https://www.ia.omron.com/products/family/389/specification.html

G9SB Safety Relay Unit/Lineup | OMRON Industrial A...

...hannels Reset mode Input type Rated voltage Model DPST-NO None 2 channels Auto-reset Inverse 24 VAC/VDC G9SB-2002-A 1 channel or 2 channels + common G9SB-200-B 2 channels Manual reset Inverse...

https://www.ia.omron.com/products/family/390/lineup.html

G9SB Safety Relay Unit/Specifications | OMRON Indu...

...7, 2022 Ratings Power Input Model G9SB-200[]-[] G9SB-3010 G9SB-301[]-[] Power supply voltage 24 VAC/24 VDC 24 VDC 24 VAC/24 VDC Operating voltage range 85% to 110% of rated power sup...

https://www.ia.omron.com/products/family/390/specification.html

TM S Series OMRON TM Collaborative Robot, S Series...

... and Humidity 0 to 50°C, 85% max. (with no condensation) Motor Power Supply AC Units 100 to 240 VAC, 50/60 HZ 200-240 VAC, 50-60 Hz DC Units 24 to 60 VDC 48-60 VDC I/O Interface 2×CO...

https://www.ia.omron.com/products/family/3911/specification.html

D40A-2 Non-Contact Safety Door Switch/Specificatio...

...in. (by 500 VDC megger) Dielectric strength (Between all conductive parts and switch case) 1000 VAC for 1 min Rated impulse withstand voltage 1 kV Vibration resistance Frequency: 10 to 55 Hz ...

https://www.ia.omron.com/products/family/3920/specification.html

A4E Enabling Switch/Specifications | OMRON Industr...

...L/CSA (UL508, CSA C22.2 No.14), CCC (GB/T 14048.5) 300 mA at 24 VDC (Inductive load) 1 A at 125 VAC (Resistive load) Ratings Rated insulation voltage 250 V Rated ON current 2.5 A Rated load 2...

https://www.ia.omron.com/products/family/396/specification.html

E3S-C Oil-resistive, Long-range Photoelectric Sens...

... (with no condensation) Insulation resistance 20 MΩ min. (at 500 VDC) Dielectric strength 1,000 VAC, 50/60 Hz for 1 min Vibration resistance Destruction: 10 to 2,000 Hz, 1.5-mm double amplitu...

https://www.ia.omron.com/products/family/412/specification.html

E3JM Built-in Power Supply Photoelectric Sensor/Sp...

...Relay output (E3JM-[][]M4 (T)(-[]) model): 24 to 240 VDC±10%, ripple (p-p): 10% max. 100 to 240 VAC±10%, 50/60 Hz DC SSR output (E3JM-[][]S4 (T)(-[]) model): 12 to 240 VDC±10%, ripple (p-p): ...

https://www.ia.omron.com/products/family/421/specification.html

F3W-D Picking Sensor/Specifications | OMRON Indust...

... (with no condensation) Insulation resistance 20 MΩ min. (at 500 VDC) Dielectric strength 1,000 VAC 50/60 Hz for 1 min Vibration resistance (destruction) 10 to 50 Hz, 1.5-mm double-amplitude ...

https://www.ia.omron.com/products/family/424/specification.html

E2EZ Chip-immune Inductive Proximity Sensor/Specif...

...tance 50 MΩ min. (at 500 VDC) between current-carrying parts and case Dielectric strength 1,000 VAC, 50/60 Hz for 1 minute between current-carrying parts and case Vibration resistance Destruc...

https://www.ia.omron.com/products/family/454/specification.html

E2EY Aluminum-detecting Proximity Sensor/Specifica...

...tance 50 MΩ min. (at 500 VDC) between current-carrying parts and case Dielectric strength 1,000 VAC, 50/60 Hz for 1 minute between current-carrying parts and case Vibration resistance Destruc...

https://www.ia.omron.com/products/family/457/specification.html

E2K-X Cylindrical Proximity Sensor/Specifications ...

...e *2 (operating voltage range) E and F Models: 12 to 24 VDC (10 to 30 VDC) Y Models: 100 to 220 VAC (90 to 250 VAC) Current consumption E and F Models: 15 mA max. Leakage current Y M...

https://www.ia.omron.com/products/family/471/specification.html

E2K-F Flat Proximity Sensor/Specifications | OMRON...

...istance 50 MΩ min. (at 500 VDC) between current-carrying parts and case Dielectric strength 500 VAC, 50/60 Hz for 1 min between current-carrying parts and case Vibration resistance Destructio...

https://www.ia.omron.com/products/family/472/specification.html

TL-L Ultra-long Sensing-distance Proximity Sensor/...

...sistance 5 MΩ min. (at 500 VDC) between current-carrying parts and case Dielectric strength 500 VAC, 50/60 Hz for 1 min between current-carrying parts and case Vibration resistance Destructio...

https://www.ia.omron.com/products/family/479/specification.html

TL-LP / LY Long-distance Proximity Sensor/Specific...

...tage (operating voltage range * ) 12 to 24 VDC (10 to 30 VDC), ripple (p-p) 10% max. 100 to 220 VAC (90 to 250 VAC), 50/60 Hz Current consumption 10 mA max. (with no load) --- Leakag...

https://www.ia.omron.com/products/family/480/specification.html

GLS Magnetic Proximity Sensor/Specifications | OMR...

...150 mΩ max. 250 mW max. (including conductor resistance of lead wire) Dielectric strength 1,000 VAC for 1 min between terminals and case Life expectancy 50,000,000 times min. with 0.1-A resis...

https://www.ia.omron.com/products/family/481/specification.html

F92A Inductive Coupler/Specifications | OMRON Indu...

...lation resistance 50 MΩ min. (at 500 VDC) between lead wires and case Dielectric strength 1,000 VAC, 50/60 Hz for 1 minute between lead wires and case Vibration resistance (destruction) 10 to...

https://www.ia.omron.com/products/family/482/specification.html

E6B2-C Incremental 40-mm-dia. Rotary Encoder/Speci...

...istance 20 MΩ min. (at 500 VDC) between current-carrying parts and case Dielectric strength 500 VAC, 50/60 Hz for 1 min between current-carrying parts and case Vibration resistance Destructio...

https://www.ia.omron.com/products/family/487/specification.html