Site Search | Product Search | IA Global Search |
...tance 50 MΩ min. (at 500 VDC) between current-carrying parts and case Dielectric strength 1,000 VAC, 50/60 Hz for 1 minute between current-carrying parts and case Vibration resistance Destruc...
https://www.ia.omron.com/products/family/3544/specification.html
...max.) Insulation resistance 1,000 MΩ min. (at 500 VDC) *1 Dielectric strength (connector) 1,500 VAC for 1 min (leakage current: 1 mA max.) Degree of protection IP67 (IEC 60529) and IP67G (JIS...
https://www.ia.omron.com/products/family/3547/specification.html
...ns Catalog last update: August 20, 2014 Switching capacity (resistive load) 3.3 to 28 VDC or 50 VAC 1 mA to 0.1 A Continuous carry current 1 A max. Contact resistance 300 mΩ max. Insulation r...
https://www.ia.omron.com/products/family/355/specification.html
...ons Catalog last update: August 20, 2014 Model A7PS A7PH Switching capacity (resistive load) 50 VAC or 3.3 to 28 VDC 1 mA to 0.1 A 125 VAC or 3.3 to 28 VDC 10 μA to 0.15 A Continuous...
https://www.ia.omron.com/products/family/356/specification.html
...thods Power supply voltage Dimensions Communications KM-N3-FLK Single-phase, 2-wire: 100 to 277 VAC Single-phase, 3-wire: 100 to 240 VAC (L-N), 200 to 480 VAC (L-L) Three-ph...
... configuration Outer dimensions 1100(W) ×1470(D)×1500(H)mm Weight 800kg Power supply 200 to 240 VAC (single phase), voltage fiuctuation range ±10% Line height 900±20mm Air supply pressure 0.3...
https://www.ia.omron.com/products/family/3653/specification.html
...rox. 3,100 kg Approx. 5,350 kg Conveyor height 900 ±20 mm Power supply Single phase, 200 to 240 VAC, 50/60 Hz Rated power 2.4kVA 2.58kVA X-ray leakage Less than 0.5 µSv/h Air supply 0.4 to 0....
https://www.ia.omron.com/products/family/3683/specification.html
...models, contact your nearest OMRON representative. Rated voltage Rated current Model number 250 VAC 250 VDC 3 A S8V-NFS203 6 A S8V-NFS206 Mounting Brackets Name Model number Front-mounting br...
...ember 13, 2023 Ratings and Characteristics Rated current 3 A 6 A Rated voltage Single-phase 250 VAC 50/60 Hz *1, 250 VDC I/O characteristics Leakage current 1.0 mA max. (250 VAC/60 H...
https://www.ia.omron.com/products/family/3688/specification.html
...n the receiver surface). Insulation resistance 20 MΩ min. (at 500 VDC) Dielectric strength 1000 VAC 50/60 Hz 1 min Degree of protection IP67 (IEC standard) Vibration resistance Operating limi...
https://www.ia.omron.com/products/family/3697/specification.html
...max.) Insulation resistance 1,000 MΩ min. (at 500 VDC) *1 Dielectric strength (connector) 1,500 VAC for 1 minute (leakage current: 1 mA max.) Degree of protection IP67 (IEC60529) IP69K (ISO20...
https://www.ia.omron.com/products/family/3701/specification.html
...ories Type Model MS-Connect 210, Connectivity Box with Display FIS-0210-0001G Relay Module, 120 VAC, 3 Amp Output, Series 70, Type SM, for MS-Connect 210 98-000013-04 Relay Module, 240 ...
...Plug, NPN output, Cable length 2m 99-9000016-01 Power Supplies Type Model Power Supply, 100-240 VAC, +24 VDC, M12 12-pin Socket 97-000012-01 Power Supply, 100-240 VAC, +24 VDC, M12 1...
...Plug, NPN output, Cable length 2m 99-9000016-01 Power Supplies Type Model Power Supply, 100-240 VAC, +24 VDC, M12 12-pin Socket 97-000012-01 Power Supply, 100-240 VAC, +24 VDC, M12 1...
...Insulation Resistance 20 MΩ min. between isolated circuits (at 100 VDC) Dielectric Strength 510 VAC between isolated circuits for 1 minute with a leakage current of 5 mA max. Applicable Stand...
https://www.ia.omron.com/products/family/3727/specification.html
... 14) (A600) Rated voltage Carry current Current (A) Volt-amperes (VA) Make Break Make Break 120 VAC 240 VAC 480 VAC 600 VAC 10 A 60 30 15 12 6 3 1.5 1.2 7,200 720 C...
https://www.ia.omron.com/products/family/374/specification.html
...put current Maximum boost current Model 240 W Three-phase / single-phase / two-phase 200 to 240 VAC (Allowable range: Three-phase / single-phase / two-phase 170 to 264 VAC, 240 to 35...
...10 M min. (at 500 VDC) Between lead wire conductor and frame Insulation withstand voltage 1,500 VAC (1 minute) Between input terminal and frame Ambient operating temperature -20 to 75°C (with...
https://www.ia.omron.com/products/family/3759/specification.html
... 10 MΩ min. (at 500 VDC) Between lead wire conductor and frame Insulation withstand voltage 500 VAC (1 minute) Between lead wire conductor and frame Ambient operating temperature -20 to +70°C...
https://www.ia.omron.com/products/family/3760/specification.html
... voltage Rated supply voltage 1.7 W max. (Exclude sensor power) Output UL Listed Rated load 250 VAC 5 A cosφ=1 30 VDC 5A L/R=0ms Rated carry current 5 A Max. switching voltage 250 ...
https://www.ia.omron.com/products/family/3761/specification.html