...tion Features Lineup Specifications Dimensions Catalog last update: March 1, 2019 Ratings Rated input voltage K8DS-PU1 3-wire 3-phase mode: 200, 220, 230, or 240 VAC K8DS-PU2 3-wire 3-phase m...
https://www.ia.omron.com/products/family/3383/specification.html
...tion Features Lineup Specifications Dimensions Catalog last update: April 1, 2019 Ratings Rated input voltage K8AK-PA1 Three-phase, three-wire Mode: 200, 220, 230 and 240 VAC Three-phase, fou...
https://www.ia.omron.com/products/family/3384/specification.html
...ked.) Muting Output B Dark-ON (Muting Output B is enabled when MUTE B trigger beam is blocked.) Input Voltage ON Voltage [MUTE Enable] Vs to Vs-3 V (sink current 5 mA max.) * OFF Voltage [MUT...
https://www.ia.omron.com/products/family/3411/specification.html
... • Request: 492 bytes • Response: 496 bytes Maximum NX output data size: • 490 bytes Maximum NX input data size: • 496 bytes Modulation Baseband Link speed 100 Mbps Physical layer 100BASE-TX ...
https://www.ia.omron.com/products/family/3412/specification.html
...ted battery type Ratings, Characteristics, and Functions Capacity 120 W 240 W 360 W 480 W *4 DC input Rated input voltage 24 VDC Input voltage range When standard voltage se...
https://www.ia.omron.com/products/family/3450/specification.html
...te: For details on normal stock models, contact your nearest OMRON representative. Power rating Input voltage Output voltage (VDC) Output current Built- in fan Model with terminal block facin...
...d Functions Power rating 30 W 60 W 120 W Output voltagec (DC) 24 V 24 V 24 V Efficiency 115 VAC input *1 87% typ. 87% typ. 90% typ. 230 VAC input *1 86% typ. 89% typ. 92% typ. ...
https://www.ia.omron.com/products/family/3485/specification.html
...ed voltage Power reset Minimum power-OFF time: 0.1 s Reset voltage 10% of rated voltage Voltage input 24 to 240 VAC/DC High level: 20.4 to 264 VAC/DC, Low level: 0 to 2.4 VAC/DC *3 Power cons...
https://www.ia.omron.com/products/family/3486/specification.html
...oltage (altitude: 2,000 m max.) 4 kV (at 240 VAC) Conditional short-circuit current 1,000 A I/O Input None Output Control output The output is turned ON/OFF according to the operating mode wh...
https://www.ia.omron.com/products/family/3487/specification.html
...oltage (altitude: 2,000 m max.) 4 kV (at 240 VAC) Conditional short-circuit current 1,000 A I/O Input None Output Control output Output is turned ON/OFF according to the time set on the ON ti...
https://www.ia.omron.com/products/family/3488/specification.html
...oltage (altitude: 2,000 m max.) 4 kV (at 240 VAC) Conditional short-circuit current 1,000 A I/O Input None Output Control output The star output is turned OFF when the dial set value is reach...
https://www.ia.omron.com/products/family/3489/specification.html
...oltage (altitude: 2,000 m max.) 4 kV (at 240 VAC) Conditional short-circuit current 1,000 A I/O Input None Output Control output The Timer operates as soon as the Timer is turned ON. The Time...
https://www.ia.omron.com/products/family/3490/specification.html
...ustrial Automation Features Lineup Specifications Dimensions Catalog last update: March 1, 2019 Input Range Model Range *1 Connection terminal Setting range Input impedance ...
https://www.ia.omron.com/products/family/3491/specification.html
...ustrial Automation Features Lineup Specifications Dimensions Catalog last update: March 1, 2019 Input Range Model Range *1 Connection terminal Setting range Input impedance ...
https://www.ia.omron.com/products/family/3492/specification.html
...ustrial Automation Features Lineup Specifications Dimensions Catalog last update: March 1, 2019 Input Range Model Range * Connection terminal Setting range Input impedance Overload c...
https://www.ia.omron.com/products/family/3493/specification.html
...ustrial Automation Features Lineup Specifications Dimensions Catalog last update: March 1, 2019 Input Range Model Range * Connection terminal Setting range Input impedance Overload c...
https://www.ia.omron.com/products/family/3494/specification.html
... MΩ min. Between all external terminals and the case Between all power supply terminals and all input terminals Between all power supply terminals and all output terminals Between all ...
https://www.ia.omron.com/products/family/3495/specification.html
...tion Features Lineup Specifications Dimensions Catalog last update: March 1, 2019 Ratings Rated input voltage 3-phase, 200 to 480 VAC (3-wire) Input load Approx. 2.6 VA Rated insulat...
https://www.ia.omron.com/products/family/3496/specification.html
...tion Features Lineup Specifications Dimensions Catalog last update: March 1, 2019 Ratings Rated input voltage K8DT-PM1[]N: Three-phase, three-wire Mode: 200, 220, 230, or 240 VAC K8DT-PM2[]N:...
https://www.ia.omron.com/products/family/3497/specification.html
...tion Features Lineup Specifications Dimensions Catalog last update: March 1, 2019 Ratings Rated input voltage K8DT-PZ1[]N: Three-phase, three-wire Mode: 200, 220, 230, or 240 VAC K8DT-PZ2[]N:...