G3PE (Three-phase) Solid State Contactors for Heat...

... + 1 ms max. Release time 1/2 of load power source cycle + 1 ms max. Output ON voltage drop 1.6 V (RMS) max. Leakage current * 10 mA max. (at 200 VAC) Insulation resistance 100 M Ω min. (at 5...

https://www.ia.omron.com/products/family/2002/specification.html

H3DS Solid-state Timer/Specifications | OMRON Indu...

... 3), 8 kV air discharge (level 3) Immunity RF-interference from AM Radio Waves: EN61000-4-3: 10 V/m (80 MHz to 1 GHz) (level 3) Immunity Burst: EN61000-4-4: 2 kV power port and output port (l...

https://www.ia.omron.com/products/family/201/specification.html

G3PW Single-phase Power Controller/Specifications ...

...onditions ON: 1 kΩ max., OFF: 100 kΩ min. Non-contact input conditions ON residual voltage: 1.0 V max., OFF leakage current: 0.1 mA max. Current flow Approx. 1.1 mA (per input) Output voltage...

https://www.ia.omron.com/products/family/2011/specification.html

ZG2 Smart Sensor (2D Measurement Sensor)/Specifica...

...t voltage or current (using the sliding switch on the bottom surface) Voltage output: -10 to 10 V, output impedance: 40 Ω Current output: 4 to 20 mA, maximum load resistance: 300 Ω Judgment o...

https://www.ia.omron.com/products/family/2041/specification.html

CRT1-VAD04[][] / VDA02[][] Analog I/O Slave Units ...

...nectors) CRT1-VAD04ML Item Specification Voltage input Current input Input signal ranges 0 to 5 V 1 to 5 V 0 to 10 V -10 to 10 V 0 to 20 mA 4 to 20 mA Maximum signa...

https://www.ia.omron.com/products/family/2042/specification.html

CJ1W-NC[][]4 CJ-series Position Control Units (Hig...

...umption (A) Model Stand- ards Control method/ Control output interface Number of control axes 5 V system 24 V system CJ1 Special I/O Units Position Control Units (High- Speed type) P...

https://www.ia.omron.com/products/family/2051/lineup.html

CJ1W-ID / IA CJ-series Input Units/Lineup | OMRON ...

...s I/O points Input voltage and current Commons External con- nection No. of words allo- cated 5 V 24 V CJ1 Basic I/O Units DC Input Units 8 inputs 12 to 24 VDC, 10 mA Independent con...

https://www.ia.omron.com/products/family/2054/lineup.html

CJ1W-OC / OA / OD CJ-series Output Units/Lineup | ...

...l Stand- ards Output type I/O points Maximum switching capacity Commons External con- nection 5 V 24 V CJ1 Basic I/O Units Relay Contact Output Units --- 8 outputs 250 VAC/ 24 VDC, 2...

https://www.ia.omron.com/products/family/2055/lineup.html

CJ1W-MD CJ-series Mixed I/O Units/Lineup | OMRON I...

...oints Input voltage, Input current Commons Ex- ternal con- nec- tion No. of words allo- cated 5 V 24 V Maximum switching capacity CJ1 Basic I/O Units DC Input/ Tran- sistor Output Un...

https://www.ia.omron.com/products/family/2056/lineup.html

CJ1W-MD CJ-series Mixed I/O Units/Specifications |...

... Leakage Current 0.1 mA max. ON Voltage/ON Current 14.4 VDC min./3 mA min. Residual Voltage 1.5 V max. OFF Voltage/OFF Current 5 VDC max./1 mA max. ON Response Time 0.1 ms max. ON Response Ti...

https://www.ia.omron.com/products/family/2056/specification.html

CP1E CP-series CP1E CPU Units/Specifications | OMR...

...wer         consumption for CPU Units with DC power.         Formula: DC power consumption = (5 V current consumption × 5 V/70% (internal power efficiency) + 24V current         cons...

https://www.ia.omron.com/products/family/2064/specification.html

H5S Digital Time Switch/Specifications | OMRON Ind...

...circuits) 1,000 VAC, 50/60 Hz for 1 min (between non-continuous contacts) Noise immunity ±1,500 V (between power terminals, for AC power models), ±500 V (between power terminals, for...

https://www.ia.omron.com/products/family/217/specification.html

H7E[]-N Self-powered Totalizer/Specifications | OM...

...o voltage input Maximum short-circuit impedance: 10 kΩ max. Short-circuit residual voltage: 0.5 V max. Minimum open impedance: 750 kΩ min. Reset input No voltage input Maximum short-circuit i...

https://www.ia.omron.com/products/family/229/specification.html

61F-G[]N Floatless Level Switch (Compact Type)/Spe...

...el name represents G, G1, G2, G3, G4, or I. *2. The length when using completely insulated, 600-V, 3-core (0.75 mm 2 ) cabtire cables. Usable cable lengths will        become shorter as the c...

https://www.ia.omron.com/products/family/243/specification.html

61F-G[] Floatless Level Switch (Basic Type)/Lineup...

...ower supply voltages. 61F-G G G1 G2 G3 G4 I Voltage Model Model Model Model Model Model 120/240 V 61F-G * 120/240 VAC 61F-G1 * 120/240 VAC 61F-G2 * 120/240 VAC 61F-G3 * 120/240 VAC 61F-G4 * 1...

https://www.ia.omron.com/products/family/244/lineup.html

NE1A-SCPU0[]-EIP Safety Network Controller/Specifi...

...tput type Sourcing outputs (PNP) Rated output current 0.5 A max./output ON residual voltage 1.2 V max. between each output terminal and V2 Leakage current 0.1 mA max. Test Output Specificatio...

https://www.ia.omron.com/products/family/2621/specification.html

CRT1B-[]D02JS(-1) / []D04JS(-1) Bit Slave Units wi...

...ternal I/O common NPN PNP NPN PNP ON voltage 10.5 VDC min. (between each input terminal and the V terminal) 10.5 VDC min. (between each input terminal and the G terminal) 10.5 VDC min. (betwe...

https://www.ia.omron.com/products/family/2629/specification.html

CJ1W-NC[]81 / []82 CJ-series Position Control Unit...

...rs allocated Current consump- tion (A) Model Stand- ards Control output interface No. of axes 5 V 24 V CJ1 CPU Bus Units Position Control Units with EtherCAT interface Control comman...

https://www.ia.omron.com/products/family/2643/lineup.html

KM50-C Smart Power Monitor/Specifications | OMRON ...

...rated input, rated frequency, and a power factor of 1) Reactive power formula: Reactive power = v × i × sin θ * "v" is the instantaneous voltage and "i" is the instantaneous current....

https://www.ia.omron.com/products/family/2646/specification.html

E3X-SD / NA Simple Fiber Amplifier Unit/Lineup | O...

...red. Appearance Applicable models Model Quantity E3X-SD[] E3X-NA[] E3X-NA[]F E39-L143 1 E3X-NA[]V E39-L148 End Plate End Plates are not provided with the Fiber Amplifier Unit. Order End Plate...

https://www.ia.omron.com/products/family/2647/lineup.html