| IAグローバル検索 |
...ut signal *4 Voltage input Current input Number of analog inputs 4 Input signal range *3 1 to 5 V 0 to 5 V 0 to 10 V - 10 to 10 V 4 to 20 mA Maximum rated input (fo...
https://www.ia.omron.com/products/family/1670/specification.html
... 10% to 90% (with no condensation) Current consumption Name Model Current consumption (power) 5 V 26 V Isolated-type Pulse Input Unit CS1W-PPS01 0.20 A (1.00 W) 0.16 A (4.2 W) (Refer...
https://www.ia.omron.com/products/family/1671/specification.html
...Commu- nications cable Commu- nications type Duplex support Max. Units mountable per CPU Unit 5 V DC 26 V DC CS1 CPU Bus Unit Controller Link Unit Wired shielded twisted- pair cable ...
...0 g 300 g (excluding mounting bracket) 300 g (excluding mounting bracket) Current consumption 5 V in PLC 0.33 A 0.52 A 0.65 A 26 V in PLC - - - External 24 V - 0.20 A 0.26 A...
https://www.ia.omron.com/products/family/1681/specification.html
...ltage Power consumption (approx.) 50 Hz 60 Hz Armature OFF Armature ON % of rated voltage AC 24 V 43.5 mA 37.4 mA 253 Ω 0.81 1.55 80% max. 30% max. 110% 0.9 VA at 60 Hz 48 V 21.8 mA ...
https://www.ia.omron.com/products/family/1731/specification.html
...tion With polarity No polarity Control output Switching capacity 3 to 100 mA Residual voltage 3 V max. (Load current: 100 mA max., Cable length: 2 m) 5 V max. (Load current: 100 mA m...
https://www.ia.omron.com/products/family/1760/specification.html
...l output Load power supply voltage: 30 VDC max., Load current: 100 mA max. (Residual voltage: 2 V max.) Open-collector output (NPN/PNP output depending on model) Light-ON/Dark-ON switch selec...
https://www.ia.omron.com/products/family/1764/specification.html
...Z-2A2B-02Z-R 4 poles + 2 poles (Relay unit + auxiliary contact) NO contact Relay AC-1: 40 A 440 V 50/60 Hz AC-3: 16 A 440 V 50/60 Hz DC-1: 5 A 110 V Auxiliary Contact AC-15:...
https://www.ia.omron.com/products/family/1767/specification.html
...(Length: 5.0 m) XW2Z-500S-CV Connects Personal Computers, D-Sub 9-pin (Length: 2.0 m) XW2Z-200S-V Connects Personal Computers, D-Sub 9-pin (Length: 5.0 m) XW2Z-500S-V Note: 1. For de...
...Setting range: 0 to 255) External analog input 1 input (Resolution: 1/256, Input range: 0 to 10 V), not isolated Note: The memory areas for CJ-series Special I/O Units and CPU Bus Units are a...
https://www.ia.omron.com/products/family/1778/specification.html
... inputs Internal I/O common NPN PNP ON voltage 15 VDC min. (between each input terminal and the V terminal) 15 VDC min. (between each input terminal and the G terminal) OFF voltage 5 VDC max....
https://www.ia.omron.com/products/family/1822/specification.html
...nputs Internal I/O common NPN PNP ON voltage 10.5 VDC min. (between each input terminal and the V terminal) 10.5 VDC min. (between each input terminal and the G terminal) OFF voltage 5 VDC ma...
https://www.ia.omron.com/products/family/1823/specification.html
...tions Item Specification Voltage input Current input Model CRT1-AD04 Input signal ranges 0 to 5 V 1 to 5 V 0 to 10 V -10 to 10 V 0 to 20 mA 4 to 20 mA Maximum signa...
https://www.ia.omron.com/products/family/1825/specification.html
...l output Load power supply voltage: 30 VDC max., Load current: 100 mA max. (Residual voltage: 2 V max.) Open-collector output (NPN/PNP output depending on model) Light ON/Dark ON switch selec...
https://www.ia.omron.com/products/family/1853/specification.html
...e current --- 0.8 mA max. Control output Load current 100 mA max. 3 to 50 mA Residual voltage 2 V max. (Load current: 100 mA, Cable length: 2 m) 3 V max. (Load current: 50 mA, Cable ...
https://www.ia.omron.com/products/family/1865/specification.html
... NPN open collector Control output Load current *2 200 mA max. (32 VDC max.) Residual voltage 2 V max. (under load current of 200 mA with cable length of 2 m) Indicator Operation indicator (Y...
https://www.ia.omron.com/products/family/1883/specification.html
...urrent Ie AC-15: Ue: 250 VAC, Ie: 5 A DC-13: Ue: 30 VDC, Ie: 1.5 A Rated insulation voltage 250 V Rated impulse withstand voltage (altitude: 2,000 m max.) 4 kV (at 240 VAC) Conditional short-...
https://www.ia.omron.com/products/family/1890/specification.html
..., Ie: 3 A AC-13: Ue: 250 VAC, Ie: 5 A DC-13: Ue: 30 VDC, Ie: 0.5 A Rated insulation voltage 250 V Rated impulse withstand voltage (altitude: 2,000 m max.) 4 kV (at 240 VAC) Conditional short-...
https://www.ia.omron.com/products/family/1891/specification.html
...(Length: 5.0 m) XW2Z-500S-CV Connects Personal Computers, D-Sub 9-pin (Length: 2.0 m) XW2Z-200S-V Connects Personal Computers, D-Sub 9-pin (Length: 5.0 m) XW2Z-500S-V Note: 1. For de...
...5%/0% at 10,000 Hz to 32,800 Hz) Analog input 2 input (Resolution: 1/1000, Input range: 0 to 10 V). Not isolated. CP1L CPU Unit (M/L Type) Type CP1L-M60 (60 points) CP1L-M40 (40 points) CP1L-...
https://www.ia.omron.com/products/family/1916/specification.html