FAQ02231 for Basic Switches | OMRON Industrial Aut...
...gh switching speed shortens the time arcing is maintained. Contact wear and damage are reduced, so stable characteristics can be obtained. Large-capacity switching can be performed with compa...

https://www.ia.omron.com/support/faq/answer/29/faq02231/

faq02946
...gure shows, the Actuator fulcrum is in a different position from that of the standard Switches, so the internal movement is reversed. Even in the free position, the pin plunger is continuousl...

https://www.ia.omron.com/support/faq/answer/29/faq02946/

faq03149
...ches available? Answer  There is no definition of high-humidity processing for Basic Switches, so OMRON does not make such switches. Use standard models. 61F-G[]N Improved Design for a More ...

https://www.ia.omron.com/support/faq/answer/29/faq03149/

FAQ03331 for Basic Switches | OMRON Industrial Aut...
...rotary-action operation. Special-purpose Basic Switches are designed for specific applications, so they are limited to use, for example, as power switches for doors. Next, select the maximum ...

https://www.ia.omron.com/support/faq/answer/29/faq03331/

FAQ02105 for Limit Switches | OMRON Industrial Aut...
...tents FAQ No. FAQ02105 Related Contents Primary Contents Question Can WLNJ Limit Switch be used so that a bent coil spring becomes straight after striking the dog? Answer  Do not use the WLN...

https://www.ia.omron.com/support/faq/answer/30/faq02105/

faq02122
...is grounded? Answer  No, it must be grounded. The socket unit and the lead wire are insulated, so the lead wires must be grounded. 61F-G[]N Improved Design for a More Lightweight Constructio...

https://www.ia.omron.com/support/faq/answer/30/faq02122/

faq02149
...r to be caught or accumulate. WLNJ-30: The coil spring consists of three tightly wrapped wires, so there is almost no flexibility in the rod. Also, no gaps form in the coil spring. Reference ...

https://www.ia.omron.com/support/faq/answer/30/faq02149/

faq02990
... OF for a WLH12 with a roller lever length of 38 mm is 9.81 N (the OF listed in the datasheet), so the fixed torque is calculated as OF x R. Dividing this by R' (89 mm in this example), which...

https://www.ia.omron.com/support/faq/answer/30/faq02990/

FAQ00692 for Level Switches | OMRON Industrial Aut...
...d with a utility knife. Leave the insulation intact on the inside. (b)Strip back the insulation so that the enough wire is exposed to fit into the sleeve in the configuration shown in Figure ...

https://www.ia.omron.com/support/faq/answer/33/faq00692/

FAQ00702 for Level Switches | OMRON Industrial Aut...
...uch as fine sandpaper. Use a cloth to wipe off the residue. The electrodes are stainless steel, so it is also acceptable to use a commercial chemical cleanser, but be sure that the liquid in ...

https://www.ia.omron.com/support/faq/answer/33/faq00702/