S8VK-S S8VK-S (30/60/120/240/480-W Models)/Specifi...

...d Functions Power rating 30 W 60 W 120 W Output voltagec (DC) 24 V 24 V 24 V Efficiency 115 VAC input *1 87% typ. 87% typ. 90% typ. 230 VAC input *1 86% typ. 89% typ. 92% typ. ...

https://www.ia.omron.com/products/family/3485/specification.html

H3DT-N / -L Multi-range, Multi-mode Timer/Specific...

...ed voltage Power reset Minimum power-OFF time: 0.1 s Reset voltage 10% of rated voltage Voltage input 24 to 240 VAC/DC High level: 20.4 to 264 VAC/DC, Low level: 0 to 2.4 VAC/DC *3 Power cons...

https://www.ia.omron.com/products/family/3486/specification.html

H3DT-A Power ON-delay Timer/Specifications | OMRON...

...oltage (altitude: 2,000 m max.) 4 kV (at 240 VAC) Conditional short-circuit current 1,000 A I/O Input None Output Control output The output is turned ON/OFF according to the operating mode wh...

https://www.ia.omron.com/products/family/3487/specification.html

H3DT-F Twin Timer/Specifications | OMRON Industria...

...oltage (altitude: 2,000 m max.) 4 kV (at 240 VAC) Conditional short-circuit current 1,000 A I/O Input None Output Control output Output is turned ON/OFF according to the time set on the ON ti...

https://www.ia.omron.com/products/family/3488/specification.html

H3DT-G Star-delta Timer/Specifications | OMRON Ind...

...oltage (altitude: 2,000 m max.) 4 kV (at 240 VAC) Conditional short-circuit current 1,000 A I/O Input None Output Control output The star output is turned OFF when the dial set value is reach...

https://www.ia.omron.com/products/family/3489/specification.html

H3DT-H Power OFF-delay Timer/Specifications | OMRO...

...oltage (altitude: 2,000 m max.) 4 kV (at 240 VAC) Conditional short-circuit current 1,000 A I/O Input None Output Control output The Timer operates as soon as the Timer is turned ON. The Time...

https://www.ia.omron.com/products/family/3490/specification.html

K8DT-AS Single-phase Current Relay/Specifications ...

...ustrial Automation Features Lineup Specifications Dimensions Catalog last update: March 1, 2019 Input Range Model Range *1 Connection terminal Setting range Input impedance ...

https://www.ia.omron.com/products/family/3491/specification.html

K8DT-AW Single-phase Overcurrent/Undercurrent Rela...

...ustrial Automation Features Lineup Specifications Dimensions Catalog last update: March 1, 2019 Input Range Model Range *1 Connection terminal Setting range Input impedance ...

https://www.ia.omron.com/products/family/3492/specification.html

K8DT-VS Single-phase Voltage Relay/Specifications ...

...ustrial Automation Features Lineup Specifications Dimensions Catalog last update: March 1, 2019 Input Range Model Range * Connection terminal Setting range Input impedance Overload c...

https://www.ia.omron.com/products/family/3493/specification.html

K8DT-VW Single-phase Overvoltage/Undervoltage Rela...

...ustrial Automation Features Lineup Specifications Dimensions Catalog last update: March 1, 2019 Input Range Model Range * Connection terminal Setting range Input impedance Overload c...

https://www.ia.omron.com/products/family/3494/specification.html

K8DT-LS Conductive Level Controller/Specifications...

... MΩ min. Between all external terminals and the case Between all power supply terminals and all input terminals Between all power supply terminals and all output terminals Between all ...

https://www.ia.omron.com/products/family/3495/specification.html

K8DT-PH Phase-sequence Phase-loss Relay/Specificat...

...tion Features Lineup Specifications Dimensions Catalog last update: March 1, 2019 Ratings Rated input voltage 3-phase, 200 to 480 VAC (3-wire) Input load Approx. 2.6 VA Rated insulat...

https://www.ia.omron.com/products/family/3496/specification.html

K8DT-PM Three-phase Voltage and Phase-sequence Pha...

...tion Features Lineup Specifications Dimensions Catalog last update: March 1, 2019 Ratings Rated input voltage K8DT-PM1[]N: Three-phase, three-wire Mode: 200, 220, 230, or 240 VAC K8DT-PM2[]N:...

https://www.ia.omron.com/products/family/3497/specification.html

K8DT-PZ Three-phase Voltage, Asymmetry, and Phase-...

...tion Features Lineup Specifications Dimensions Catalog last update: March 1, 2019 Ratings Rated input voltage K8DT-PZ1[]N: Three-phase, three-wire Mode: 200, 220, 230, or 240 VAC K8DT-PZ2[]N:...

https://www.ia.omron.com/products/family/3498/specification.html

K8DT-TH Temperature Monitoring Relay/Specification...

... MΩ min. Between all external terminals and the case Between all power supply terminals and all input terminals Between all power supply terminals and all output terminals Between all ...

https://www.ia.omron.com/products/family/3499/specification.html

G70V I/O Relay Terminal/Lineup | OMRON Industrial ...

...Common Line Rated voltage Model Terminal Block Side Connector Side Push-In Plus terminal blocks Input *1 16 No internal connections NPN (- common) 24 VDC G70V-SID16P PNP (+ common) G70V-SID16...

https://www.ia.omron.com/products/family/3509/lineup.html

G70V I/O Relay Terminal/Specifications | OMRON Ind...

... last update: December 1, 2025 Specifications Main Unit (Relay) Ratings Coil Ratings (Common to Input/Output per Relay) Rated voltage (V) Rated current (mA) Coil resistance (Ω) Must operate o...

https://www.ia.omron.com/products/family/3509/specification.html

KM-N2-FLK Power Monitor/Specifications | OMRON Ind...

...phase three-wire: 2 circuits max., Three-phase four-wire: 1 circuit Power consumption 7 VA max. Input Rated input voltage (Common terminals of a power supply and a measurement voltag...

https://www.ia.omron.com/products/family/3511/specification.html

E3NX-CA Color Fiber Amplifier Unit/Lineup | OMRON ...

... Wire-saving Connector 1 output E3NX-CA6 E3NX-CA8 Advanced models Pre-wired (2 m) 2 outputs + 1 input E3NX-CA21 2M E3NX-CA51 2M Model for Sensor Communications Unit * Connector for Sensor Com...

https://www.ia.omron.com/products/family/3532/lineup.html

NX-ILM400 NX-series IO-Link Master Unit/Specificat...

...gital inputs (in SIO (DI) Mode) Internal I/O common PNP Rated voltage 24 VDC (20.4 to 28.8 VDC) Input current 5 mA typical (24 VDC) ON voltage/ON current 15 VDC min., 2 mA min. OFF voltage 5 ...

https://www.ia.omron.com/products/family/3540/specification.html