...temperature of 23°C) Thermocouple: (±0.3% of indication value or ±1°C, whichever is greater) ±1 digit max. *1 Platinum resistance thermometer: (±0.2% of indication value or ±0.8°C, whichever ...
https://www.ia.omron.com/products/family/3288/specification.html
...temperature of 23°C) Thermocouple: (±0.3% of indication value or ±1°C, whichever is greater) ±1 digit max. *1 Platinum resistance thermometer: (±0.2% of indication value or ±0.8°C, whichever ...
https://www.ia.omron.com/products/family/3289/specification.html
...emperature of 23°C) Thermocouple: (±0.3 % of indication value or ±1°C, whichever is greater) ±1 digit max. *1 Platinum resistance thermometer: (±0.2 % of indication value or ±0.8°C, whichever...
https://www.ia.omron.com/products/family/3370/specification.html
... 0.1 A Maximum load current 0.1 A/point, 0.4 A/Unit Overall accuracy (25°C) ±5% (full scale) ±1 digit Maximum inrush current 1.0 A/point max., 10 ms Leakage current 0.1 mA max. Influence of t...
https://www.ia.omron.com/products/family/3539/specification.html
...temperature of 23°C) Thermocouple: (±0.3% of indication value or ±1°C, whichever is greater) ±1 digit max. *1 Platinum resistance thermometer: (±0.2% of indication value or ±0.8°C, whichever ...
https://www.ia.omron.com/products/family/3668/specification.html
...temperature of 23°C) Thermocouple: (±0.3% of indication value or ±1°C, whichever is greater) ±1 digit max. *1 Platinum resistance thermometer: (±0.2% of indication value or ±0.8°C, whichever ...
https://www.ia.omron.com/products/family/3669/specification.html
...asured value is within the upper and lower limits. Display method Numerical value indication: 4-digit 7-segment white LED with inverting function Status indicators: The content of indication ...
https://www.ia.omron.com/products/family/3720/specification.html
....g. water, water-soluble coolants, insoluble oils) Display method Numerical value indication: 4-digit 7-segment white LED with inverting function Status indicator: The content of indication i...
https://www.ia.omron.com/products/family/3721/specification.html
...inimum interval of 10 ms) Continuous (minimum interval of 10 ms) Measuring accuracy ±0.1% FS ±1 digit max. (at 23 ±5°C) Output mode Input mode: Not 2-input independent measurement: HI-LO, ARE...
https://www.ia.omron.com/products/family/3809/specification.html
...um of the input pulse cycle multiplied by the averaging setting. Measuring accuracy ±0.1% FS ±1 digit max. (at 23 ±5°C) Tachometer Output mode HI-LO, AREA, HI-HI, LO-LO HI-HI, LO-LO Auto-zero...
https://www.ia.omron.com/products/family/3810/specification.html
...s Measurement range 0.1 to 99.9 MΩ (0.0 MΩ for less than 0.1 MΩ) Measuring accuracy ±5% rdg. ±1 digit (at ambient temperature -10 to 55°C and ambient humidity 25% to 65%) Megger voltage 50 VD...
https://www.ia.omron.com/products/family/3811/specification.html
... V AC: 0.0 to 660.0 V AC Measurement accuracy Absolute accuracy of voltage/current: ±0.5% FS ±1 digit to the input range Conditions: • When sine waves are input continuously • Variations in C...
https://www.ia.omron.com/products/family/3855/specification.html
... mounted separately) Thermocouple: (±0.1% of indication value or ±1°C, whichever is greater) ±1 digit max. *1 Platinum resistance thermometer: (±0.1% of indication value or ±0.5°C, whichever ...
https://www.ia.omron.com/products/family/3937/specification.html
...temperature of 23°C) Thermocouple: (±0.3% of indication value or ±1°C, whichever is greater) ±1 digit max. *1 Platinum resistance thermometer: (±0.2% of indication value or ±0.8°C, whichever ...
https://www.ia.omron.com/products/family/3938/specification.html
...on Sampling rate Switchable between 50 ms (default) and 5 ms Influence of temperature ±1% FS ±1 digit or less Influence of voltage Installation influence Influence of EMS Instruction range K3...
https://www.ia.omron.com/products/family/3947/specification.html
...e), current, voltage, power factor, and frequency Accuracy *1 *2 *3 Voltage *4 ±0.5% of F.S. ±1 digit Current *5 ±0.5% of F.S. ±1 digit Power ±1.0% of F.S. ±1 digit (Power f...
https://www.ia.omron.com/products/family/3955/specification.html
...play functions Output voltage display Display range: 16.3 to 32.0 V Display accuracy: 2% rdg ±1 digit max. Output current display Branch output current Display range: 0.0 to 20.0 A Branch out...
https://www.ia.omron.com/products/family/3956/specification.html
...(at 23±5°C) (See note.) Thermocouple: (±0.5% of indication value or ±1°C, whichever greater) ±1 digit max. Platinum-resistance thermometer: (±0.5% of indication value or ±1°C, whichever great...
https://www.ia.omron.com/products/family/589/specification.html
...rovement of operability This will introduce new and improved design of H7CC for easier use by 6-digit up/down keys with LED mounted. 設計 保守・メンテ 効率化(業務・作業) 省スペース 使い方 ...