CK3W-GC[][]00 Laser Interface Unit/Specifications ...
...ch in X, Y, and Z directions Insulation Resistance 20 MΩ min. between isolated circuits (at 100 VDC) Dielectric Strength 510 VAC between isolated circuits for 1 minute with a leakage current ...

https://www.ia.omron.com/products/family/3835/specification.html

V440-F 5-Megapixel C-Mount Code Reader/Specificati...
...t, New Master, and Default - Bi-Directional Inputs, Optoisolated, 4.5 - 28 V rated (10 mA [] 28 VDC) Output Signals 3 Signals: Bi-Directional, Optoisolated, 1 - 28 V rated, (I CE ...

https://www.ia.omron.com/products/family/3847/specification.html

CK3A-G305L / -G310L / -G320L CK3A-series Direct PW...
...e 240 VAC 1-Phase 110 to 240 VAC 10 Arms CK3A-G310L 3-Phase 240 VAC 1-Phase 240 VAC 1-Phase 100 VDC 20 Arms CK3A-G320L Note: The Amplifier comes with the following accessories. Customers are ...

https://www.ia.omron.com/products/family/3851/lineup.html

61F-LS Floatless Level Switch (Compact, Plug-in Ty...
...P11-ARA 8-pin 61F-LS-CP08-ARA 8-pin 24 VAC 61F-LS-CP08-ARB DC power supply 11-pin Transistor 24 VDC 61F-LS-CP11-BTC 11-pin Relay 61F-LS-CP11-BRC Accessories (Order Separately) Connectable Lev...

https://www.ia.omron.com/products/family/3852/lineup.html

61F-AO Alternate Operation Relay/Specifications | ...
... width Min. ON time: 40 ms min. Min. OFF time: 2 s min. Insulation resistance 10 MΩ min. at 500 VDC (between each terminal and power supply) Dielectric strength 2,000 VAC, 50/60 Hz for 1 min ...

https://www.ia.omron.com/products/family/3853/specification.html

61F-WL Water Leak Detector/Specifications | OMRON ...
...sistive load (cosφ = 1)) 1 A at 250 VAC (Inductive load (cosφ = 0.4)) Minimum applicable load 5 VDC, 1 mA (reference value) Ambient temperature -10 to +55°C Ambient humidity 25 to 85% RH Ambi...

https://www.ia.omron.com/products/family/3854/specification.html

XW2K-COM Ultra-Compact Common Terminal Blocks (For...
...Lineup Specifications Dimensions Catalog last update: May 9, 2022 Ratings Rated voltage 250 VAC/VDC Rated current 10 A Applicable wire *1 Stranded wire, solid wire 0.08 to 1.5 mm 2 (AWG 28 to...

https://www.ia.omron.com/products/family/3857/specification.html

G7SA Relays with Forcibly Guided Contacts/Lineup |...
...l rated voltage Model PCB terminals Flux-tight 4 poles 3PST-NO, SPST-NC 12, 18, 21, 24, 48, 110 VDC G7SA-3A1B DPST-NO, DPST-NC 12, 18, 21, 24, 48, 110 VDC G7SA-2A2B 6 poles 5PST-NO, ...

https://www.ia.omron.com/products/family/386/lineup.html

G9SX-NS Non-Contact Door Switch Controller/Lineup ...
...pe Model Instant- aneous OFF- delayed *2 2 (Semi- conductors) 0 2 (Semi- conductors) 1 1 --- 24 VDC Screw terminals G9SX-NS202-RT Spring- cage terminals G9SX-NS202-RC 2 (Semi- conductors) 3.0...

https://www.ia.omron.com/products/family/3860/lineup.html

NX-ECT101 NX-series EtherCAT® Slave Unit/Specifica...
...nd NX bus: Pulse transformer Insulation resistance 20 MΩ min. between isolated circuits (at 100 VDC) Dielectric strength 510 VAC between isolated circuits for 1 minute at a leakage current of...

https://www.ia.omron.com/products/family/3862/specification.html