Primary Contents

Site Search Results

Site Search Product Search IA Global Search
Results 701 - 710 of 5892
EE-SX95 Ultra-compact Pre-wired Photomicrosensor (...
... current: 50 mA max. OFF current: 0.5 mA max. 50 mA load current with a residual voltage of 0.7 V max. 5 mA load current with a residual voltage of 0.4 V max. Protection circuit Load...

https://www.ia.omron.com/products/family/3199/specification.html

S8VK-C Switch Mode Power Supply (60/120/240/480-W ...
... Voltage (VDC) Output current *1 Model number 60 W Single phase 100 to 240 VAC 90 to 350 VDC 24 V 2.5 A S8VK-C06024 120 W 24 V 5 A S8VK-C12024 240 W 24 V 10 A S8VK-C24024 48...

https://www.ia.omron.com/products/family/3201/lineup.html

S8VK-R Redundancy Unit/Specifications | OMRON Indu...
... A Rated output current 10 A 20 A Boost current 12 A * 24 A * Voltage drop Input to Output 0.56 V typ. 2x5 A 0.63 V typ. 1x10 A 0.67 V typ. 2x10 A 0.78 V typ. 1x20 ...

https://www.ia.omron.com/products/family/3237/specification.html

K8AK-LS Conductive Level Controller/Specifications...
...r supply voltage 24 VAC 50/60 Hz or 24 VDC 100 to 240 VAC 50/60 Hz Voltage across elec-trodes 5 V p-p (Approx. 20 Hz) Power consumption 24 VAC/DC: 2.0 VA/1.1 W max. 100 to 240 VAC: 4.6 VA max...

https://www.ia.omron.com/products/family/3240/specification.html

A22LK Guard Lock Safety Key Selector Switch/Specif...
...n category AC-15 DC-13 Rated operating current (Ie) 3 A 0.27 A Rated operating voltage (Ue) 240 V 250 V Note: Use a 10 A fuse type gI or gG that conforms to IEC60269 as a short-circu...

https://www.ia.omron.com/products/family/3276/specification.html

3Z4S-LE SV-H / VS-H1 Series High-resolution Lens f...
...cations Dimensions Catalog last update: December 11, 2014 (Unit: mm) SV-0614H SV-0814H SV-1214H V-1614H SV-2514H SV-3514H SV-5014H V-7525H SV-10028H VS-0618H1 VS-0814H1 VS-1214H1 VS-...

https://www.ia.omron.com/products/family/3282/dimension.html

3Z4S-LE SV-H / VS-H1 Series High-resolution Lens f...
...arch 10, 2025 Recom- mended camera Model Focal dis- tance (mm) Aper- ture (F No) Field of view (V × H) Closest distance (mm) Filter size Weight (g) Total length (mm) Maximum com- patible CCD ...

https://www.ia.omron.com/products/family/3282/lineup.html

VE Small Enclosed Switches/Specifications | OMRON ...
... Lineup Specifications Dimensions Catalog last update: November 19, 2014 Ratings Rated voltage (V) Non-inductive load (A) Inductive load (A) Resistive load Lamp load Inductive load Motor load...

https://www.ia.omron.com/products/family/333/specification.html

K8AK-VS Single-phase Voltage Relay/Lineup | OMRON ...
... Dimensions Catalog last update: April 1, 2014 Setting range Power supply voltage Model 1 to 10 V AC/DC 3 to 30 V AC/DC 15 to 150 V AC/DC 24 VAC/DC K8AK-VS2 24 VAC/DC 100 to...

https://www.ia.omron.com/products/family/3375/lineup.html

K8AK-VW Single-phase Overvoltage/Undervoltage Rela...
... Dimensions Catalog last update: April 1, 2014 Setting range Power supply voltage Model 1 to 10 V AC/DC 3 to 30 V AC/DC 15 to 150 V AC/DC 24 VAC/DC K8AK-VW2 24 VAC/DC 100 to...

https://www.ia.omron.com/products/family/3381/lineup.html

Results 701 - 710 of 5892