faq00736

...l Controllers to substitute 61F-GP-N8? Answer  61F-GP-N8 and 61F-GP differ in outer dimensions so the compatible Sockets and the mounting method will be different. This means that the Socket...

https://www.ia.omron.com/support/faq/answer/33/faq00736/

FAQ00738 for Level Switches | OMRON Industrial Aut...

...stance includes the wiring from the 61F Controller's inputs (electrodes) to the 61F Controller, so the two values are not necessarily the same when there is a long distance, but generally the...

https://www.ia.omron.com/support/faq/answer/33/faq00738/

FAQ00751 for Level Switches | OMRON Industrial Aut...

...through the electrodes. If the electrodes are usually submerged, galvanic corrosion will occur, so the Ultra High-sensitivity model cannot be used for control. Applications are restricted to ...

https://www.ia.omron.com/support/faq/answer/33/faq00751/

faq00755

...swer  Electrodes are sold in 1-m increments. Electrode (F03-01) There are threads at both ends so it can be cut in half and used as two Electrodes. The threads (M6) have been created by roll...

https://www.ia.omron.com/support/faq/answer/33/faq00755/

FAQ00759 for Level Switches | OMRON Industrial Aut...

... the 61F-GP-N. The voltage and current between the 61F electrodes is only about 8 VAC and 1 mA, so it is best to use a float switch contact that is for a minimal load. 61F-G[]N Improved Desig...

https://www.ia.omron.com/support/faq/answer/33/faq00759/

FAQ00844 for Level Switches | OMRON Industrial Aut...

... cable and power cable in the same duct? Answer  There is a possibility of improper operation, so avoid wiring the cables in the same duct or close together. Since there is a weak current (a...

https://www.ia.omron.com/support/faq/answer/33/faq00844/

FAQ00853 for Level Switches | OMRON Industrial Aut...

...e is no problem. In some cases, however, the tank has insulation coating on its internal walls, so make sure to check in advance that the system operates correctly. However, do not use this m...

https://www.ia.omron.com/support/faq/answer/33/faq00853/

faq03253

... However, when there are waves on the liquid surface, 61F will also repeatedly turn ON and OFF, so the lifetime of the contacts will be shorter than usual. 61F-G Example Applicable Models 61F...

https://www.ia.omron.com/support/faq/answer/33/faq03253/

FAQ00948 for Rotary Encoders | OMRON Industrial Au...

... 0, but from an intermediate code, and thus when actually using a code it must first be shifted so that it starts from 0. The example in the code table shows 36 divisions. For the change from...

https://www.ia.omron.com/support/faq/answer/34/faq00948/

FAQ00978 for Rotary Encoders | OMRON Industrial Au...

...[]H 3. Please confirm ON point of phase "Z" output on the controller side and adjust the origin so cut face "D" and phase "Z" origin of other models are not suitable. E2E Standard Sensors for...

https://www.ia.omron.com/support/faq/answer/34/faq00978/

FAQ01209 for Pressure Sensors | OMRON Industrial A...

... Pressure Sensor is ±5% FS. Converting this into voltage, ±5% × 1⁄1000 (%) × 4 V (FS) = ±0.2 V, so the line will deviate ±0.2 V max. E2E Standard Sensors for Detecting Ferrous Metals under St...

https://www.ia.omron.com/support/faq/answer/35/faq01209/

FAQ01327 for Pressure Sensors | OMRON Industrial A...

...7.5006 x 10 -3 0.10197 1 Examples: How many kgf/cm 2 is 10 Pa? Pa = 1.0197 x 10 -5 (kgf/cm 2 ), so 10 Pa = 10 -4 (kgf/cm 2 ). How many Pa is 10 kgf/cm 2 ? 1 kgf/cm 2 = 0.0980665 Mpa, ...

https://www.ia.omron.com/support/faq/answer/35/faq01327/

FAQ02207 for General Purpose Relays | OMRON Indust...

... measure the voltage on both sides of the Relay coil terminal, and set the power supply voltage so that the rated voltage is applied. If wiring is performed over a long distance in parallel w...

https://www.ia.omron.com/support/faq/answer/36/faq02207/

faq02758

...con, Sulfuric, or Organic Gas) Do not use Relays in a location where silicon gas, sulfuric gas (SO 2 or H 2 S), or organic gas is present. If Relays are stored or used for an extended period ...

https://www.ia.omron.com/support/faq/answer/36/faq02758/

faq02761

... 3 km.) Example: For MY4 Relays 100 VAC, 60 Hz, MY4 with CW Cable Answer: Value exceeds 3,000 m so there is no problem with cables up to 3 km. MY Best-selling, general-purpose relays that can...

https://www.ia.omron.com/support/faq/answer/36/faq02761/

FAQ02783 for General Purpose Relays | OMRON Indust...

...ks to their contact form. However, this theory is not applied for high power load applications, so that a single contact point without AU plating is adopted. Contact reliability in minimum lo...

https://www.ia.omron.com/support/faq/answer/36/faq02783/

faq02795

...pose Relays can be mounted? Answer  There are no restrictions. However, it is best to mount MY so that vibration and shock will not be applied in the direction of movement of the contacts. A...

https://www.ia.omron.com/support/faq/answer/36/faq02795/

FAQ02800 for General Purpose Relays | OMRON Indust...

...General Purpose Relays' lifetime? Answer  Welding, contact failure, insulation degradation and so on are cited as the measures used to judge the General Relay's lifetime. Measures used to ju...

https://www.ia.omron.com/support/faq/answer/36/faq02800/

faq02803

...s replaced with MY2N-D2? Answer  Yes, the same Sockets can be used. MY2N-D2 has coil polarity, so take care when wiring. MY Best-selling, general-purpose relays that can be selected based on...

https://www.ia.omron.com/support/faq/answer/36/faq02803/

faq02828

...gainst Leakage Current when Using Proximity Sensors and Relays Connect the bleeder resistor and so that the leakage current that normally flows through the load (Relays coil) is by-passed. AC...

https://www.ia.omron.com/support/faq/answer/36/faq02828/