Primary Contents

IAグローバル検索結果

国/地域選択

IAグローバル検索
結果 6981 - 700053814
プリント基板用リレー - 形式名索引 | オムロン制御機器

...しいただけます。 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z 0 1 2 3 4 5 6 7 8 9 関連情報 共通 生産終了品/推奨代替品 目的・仕様別選定 カタログ/マニュアル訂正 輸出該非判定 規格認証/適...

https://www.fa.omron.co.jp/products/index/relays/pcb-relays/

GT1-ID / OD Digital I/O Units/Specifications | OMR...

... Input Specifications Model GT1-ID[][] ON delay 1.5 ms max. OFF delay 1.5 ms max. ON voltage 15 V min. (between each input terminal and V or G) OFF voltage 5 V max. (between...

https://www.ia.omron.com/products/family/1080/specification.html

A16 Pushbutton Switch (Detachable) (Lighted/Non-Li...

...ED Lamp) Rated voltage Operating voltage Applicable lamp 110 VAC/VDC 100/110 VAC/VDC (90 to 121 V) A16-24DS[] LED Lamp 220 VAC/VDC 200/220 VAC/VDC (180 to 242 V) Characteristics Sock...

https://www.ia.omron.com/products/family/1101/specification.html

A165S / W Knob-type Selector Switch (Detachable) (...

...ludes a Switch and a Lamp.) Appearance Number of notches Classification Model 2 notches SPDT 24 V Solder terminals A16W-2N[]-24D-1 DPDT A16W-2N[]-24D-2 3 notches DPDT A16W-3N[]-24D-2 Switch U...

https://www.ia.omron.com/products/family/1102/lineup.html

M16 Indicator (Cylindrical 16-dia.)/Lineup | OMRON...

...) 100/110 VAC/VDC M16-[1]-T1-S 200/220 VAC/VDC M16-[1]-T2-S Note: 1. The LED built into the 100-V model is 24 VAC/VDC.           2. The LED built into the 200-V model is high-intensi...

https://www.ia.omron.com/products/family/1105/lineup.html

A22 Pushbutton Switch (Cylindrical 22/25-dia.)/Spe...

...Rated current Operating voltage Applicable lamp (BA9S/Base: 13) 110 VAC 8 mA 100 VAC (95 to 115 V) LED Lamp (A22-24A[]) 220 VAC 200 VAC (190 to 230 V) Characteristics Type Pushbutton...

https://www.ia.omron.com/products/family/1108/specification.html

A22NE-PD / A22NE-P / A22E Emergency Stop Pushbutto...

... CSA C22.2 No. 14 has been obtained. Ratings Contacts (Standard Load) Rated insulation voltage (V) Rated carry current (A) Rated voltage (V) Rated current (A) AC15 (Inductive load) A...

https://www.ia.omron.com/products/family/1111/specification.html

A3P Lighted Pushbutton Switches/Specifications | O...

...re certified. Ratings Contact Ratings Silver Alloy Contacts (for Standard Loads) Rated voltage (V) Non-inductive load (A) Inductive load (A) Resistive load Lamp load Inductive load Motor load...

https://www.ia.omron.com/products/family/1120/specification.html

D4F Small Safety Limit Switch/Specifications | OMR...

...tem AC-15 DC-13 Rated operating current (I e ) 0.75 A 0.27 A Rated operating voltage (U e ) 240 V 250 V Note: Use a 10 A fuse type gI or gG that conforms to IEC60269 as a short-circu...

https://www.ia.omron.com/products/family/1327/specification.html

E6C3-A Slim Encoder with Diameter of 50 mm/Specifi...

...put Output capacity Applied voltage: 30 VDC max. Sink current: 35 mA max. Residual voltage: 0.4 V max. (at sink current of 35 mA) Source current: 35 mA max. Residual voltage: 0.4 V m...

https://www.ia.omron.com/products/family/1347/specification.html

DRT2-[]D04CL(-1) / []D08C(-1) / []D08CL(-1) / []D1...

...D08C-1 Internal I/O common NPN PNP I/O points 8 inputs ON voltage 9 VDC min. (between input and V terminal) 9 VDC min. (between input and G terminal) OFF voltage 5 VDC max. (between input and...

https://www.ia.omron.com/products/family/1354/specification.html

D4NL Guard Lock Safety-door Switch/Specifications ...

...n category AC-15 DC-13 Rated operating current (Ie) 3 A 0.27 A Rated operating voltage (Ue) 240 V 250 V Note: Use a 10 A fuse type gI or gG that conforms to IEC60269 as a short-circu...

https://www.ia.omron.com/products/family/1357/specification.html

CJ1W-NC[][]3 CJ series Position Control Units/Line...

...nsumption (A) Model Standards Control method/ Control output interface Number of control axes 5 V system 24 V system CJ1 Special I/O Units Position control unit Open-loop control by ...

https://www.ia.omron.com/products/family/1409/lineup.html

CJ1W-NC[][]3 CJ series Position Control Units/Spec...

...c Specifications Item Model CJ1W-NC113/133 CJ1W-NC213/233 CJ1W-NC413/433 Power supply voltage 5 V DC (for the PCU itself) 24 V DC (external power supply) 5 V DC (external po...

https://www.ia.omron.com/products/family/1409/specification.html

CJ1W-TC CJ Series Temperature Control Unit/Specifi...

...% Max. switching capacity: 100 mA (per output) Leakage current: 0.3 mA max. Residual voltage: 3 V max. Temperature control method ON/OFF control or PID control with two degrees of freedom (Se...

https://www.ia.omron.com/products/family/1438/specification.html

G7S-[]-E Relays with Forcibly Guided Contacts/Spec...

...tings Safety Relay Unit Coil Rated voltage Rated current (mA) Coil resistance (Ω) Max. voltage (V) Power consumption (W) 24 VDC 30 800 110% Approx. 0.8 Note: 1. The rated current and coil res...

https://www.ia.omron.com/products/family/1446/specification.html

CJ1W-CLK CJ-series Controller Link Units/Lineup | ...

...mmuni- cations cable Communi- cations type Duplex sup- port Max. Units mountable per CPU Unit 5 V DC 24 V DC CJ1 CPU Bus Unit Controller Link Unit Wired shielded twisted-pair cable *...

https://www.ia.omron.com/products/family/1452/lineup.html

CJ1W-CLK CJ-series Controller Link Units/Specifica...

... Storage location of routing tables CPU Unit parameter area Weight 110 g Current consumption: 5 V in PLC 0.35 A * Discontinuation models in July 2012. Controller Link Support Boards (for PCI ...

https://www.ia.omron.com/products/family/1452/specification.html

DRT2-[]D08(-1) / []D16(-1) Transistor Remote I/O T...

...n NPN PNP Number of I/O points 8 inputs ON voltage 15 VDC min. (between each input terminal and V) 15 VDC min. (between each input terminal and G) OFF voltage 5 VDC max. (between each input t...

https://www.ia.omron.com/products/family/146/specification.html

D4NS, D4NS-SK Safety-door Switch/Specifications | ...

...n category AC-15 DC-13 Rated operating current (Ie) 3 A 0.27 A Rated operating voltage (Ue) 240 V 250 V Note: Use a 10 A fuse type gI or gG that conforms to IEC60269 as a short-circu...

https://www.ia.omron.com/products/family/1465/specification.html

結果 6981 - 700053814

国/地域選択

Related Contents