| Site Search | Product Search | IA Global Search |
...thed washer are provided with each Sensors. 2. The model number is laser-marked on the cable section and milled section. Shielded E2E2-X2Y[]-M4 E2E2-X5Y[]-M4 Unshielded E2E2-X5MY[]-M...
... VDC max.) 200 mA max. at 24 VDC (30 VDC max.) Residual voltage 3 V max. (Load current: 100 mA, Cable length: 2 m) 2 V max. (Load current: 200 mA, Cable length: 2 m) Indicators D1 Mo...
https://www.ia.omron.com/products/family/454/specification.html
...open-collector output, 100 mA max. (at 30 VDC) Residual voltage 2 V max. (Load current: 100 mA, Cable length: 2 m) Indicators Detection indicator (red) Operation mode (with sensing object app...
https://www.ia.omron.com/products/family/457/specification.html
...n this data sheet unless otherwise specified. Sensors TL-Q2MC1 * 2.9-dia. vinyl-insulated round cable with 3 conductors (Conductor cross section: 0.15 mm 2 , Insulator diameter: 0.9 mm), St...
...max.*2, Y Models: 10 to 200 mA Residual voltage E and F Models: 2 V max. (Load current: 200 mA, Cable length: 2 m), Y Models: Refer to Engineering Data on Data Sheet. Indicators E and F Model...
https://www.ia.omron.com/products/family/471/specification.html
... NPN open collector, 100 mA max. (at 30 VDC) Residual voltage 1.5 V max. (Load current: 100 mA, Cable length: 2 m) Indicators Detection indicator (red) Number of turns of sensitivity adjustme...
https://www.ia.omron.com/products/family/472/specification.html
..., and Z directions Degree of protection IP66 (IEC) Connection method Pre-wired Models (Standard cable length: 1m) Weight (packed state) Approx. 1.5 kg Materials Case: Aluminum die-cast, Sensi...
https://www.ia.omron.com/products/family/479/specification.html
...lerance class IT16 is used for dimensions in this data sheet. TL-LP50 TL-LY50 *1. Vinyl cabtire cable: TL-LP50: 9.4-dia. vinyl-insulated round cable with 3 conductors ...
...of 200 mA at 30 VDC 10 to 200 mA Residual voltage 3 V max. under a load current of 200 mA and a cable length of 2 m Refer to Datasheet. Indicators Operation indicator (red) Operation mode (wi...
https://www.ia.omron.com/products/family/480/specification.html
...k Model (Sensor) Name Model Set GLS-1 Sensor GLS-S1 Magnet GLS-M1 Pre-wired Model (Sensor) Name Cable length Model Set 1 m GLS-1L Sensor GLS-S1-L Note: A magnet of the Pre-wired Model can not...
...Degree of protection IP40 (IEC) IP62 (IEC) Connection method Terminal block Pre-wired (standard cable length: 1 m) Materials Sensor ABS Magnet last update: December 2, 2021...
https://www.ia.omron.com/products/family/481/specification.html
...class IT16 is used for dimensions in this data sheet. F92A-C-1 *1. 6-dia. vinyl-insulated round cable with 2 conductors (Conductor cross section: 0.5 mm 2 , Insulator diameter: 1.9 mm), ...
...ion IEC IP67, in-house standard for oil resistance Connection method Pre-wired Models (Standard cable length: 2 m) Transmittable Proximity Sensors E2E-X5C[]18, -X5B[]18 (E2E NEXT Series) E2E-...
https://www.ia.omron.com/products/family/482/specification.html
..., 100, 200, 300, 360 E6A2-CS5C (resolution) 0.5M Example: E6A2-CS5C 10P/R 0.5M 500 * Only a 2-m cable is available for the 20P/R Model. Accessories (Order Separately) Name Model Remarks Coupl...
...Hz Rise and fall times of output 1 μs max. (Control output voltage: 5 V, Load resistance: 1 kΩ, Cable length: 2 m max.) 1 μs max. (Cable length: 2 m max., Sink current: 10 mA) 0.1 μs...
https://www.ia.omron.com/products/family/487/specification.html
...T) Rise and fall times of output 1 μs max. (Control output voltage: 5 V, Load resistance: 1 kΩ, Cable length: 2 m) 1 μs max. (Cable length: 2 m, Load current: 10 mA) 0.1 μs max....
https://www.ia.omron.com/products/family/488/specification.html
... directions Degree of protection *3 IEC 60529 IP50 Connection method Pre-wired Models (Standard cable length: 0.5 m) Material Case: Zinc alloy, Main unit: Aluminum, Shaft: SUS303, Mounting Br...
https://www.ia.omron.com/products/family/489/specification.html
...tween outputs 90°± 45° between A and B (1/4 T ± 1/8 T) Rise and fall times of output 1 μs max. (Cable length: 2 m, Output current: 30 mA) 1 μs max. (Cable length: 2 m, Control output...
https://www.ia.omron.com/products/family/490/specification.html
... and fall times of output 1 μs max. (Control output voltage: 5 V, Load resistance: 1 kΩ, Output cable: 500 mm) 1 μs max. (Io = -10 mA, Is = 10 mA, Output cable: 500 mm) Starting torq...
https://www.ia.omron.com/products/family/491/specification.html
...ries (Order Separately) Servo Mounting Bracket E69-2 Note: Provided with the product. Extension Cable E69-DF5 Note: 1. The E69-DF5 (5 m) is also available with the following cable le...