| Site Search | Product Search | IA Global Search |
...er of outputs Mounting method Supply voltage Models Weekly 2 circuits Flush mounting 100 to 240 VAC H5S-WB2 24 VDC H5S-WB2D Surface mounting/ track mounting 100 to 240 VAC H5S-WFB2 2...
...ications Dimensions Catalog last update: August 3, 2015 Ratings Rated supply voltage 100 to 240 VAC (50/60 Hz) Operating voltage range 85% to 110% of rated supply voltage Power consumption Ap...
https://www.ia.omron.com/products/family/218/specification.html
...ying terminals and exposed non- current-carrying metal parts) Dielectric strength voltage 1,000 VAC, 50/60 Hz for 1 min (between currentcarrying terminals and exposed non- current-carrying me...
https://www.ia.omron.com/products/family/230/specification.html
... If you order the 61F-GN, one 61F-11 Relay Unit is included in the set. * 61F-G[]N (120/240 VAC) in this catalog have been discontinued at the end of March 2018. last update: April 2, 201...
...anks is long or where remote control is required. Supply voltage 100, 110, 120, 200, 220 or 240 VAC; 50/60 Hz Operating voltage range 85% to 110% of rated voltage InterElectrode voltage ...
https://www.ia.omron.com/products/family/244/specification.html
...dering, specify the desired operating voltage at the end of the model number. * 61F-G[]P[] (110 VAC) in this catalog have been discontinued at the end of March 2018. Accessories (Order Separa...
...such as salt water, sewage water, acid chemicals, alkali chemicals Supply voltage 100, 200, 220 VAC; 50/60 Hz Operating voltage range 85% to 110% of rated voltage Interelectrode voltage ...
https://www.ia.omron.com/products/family/246/specification.html
...Item High-sensitivity 61F-UHS Variable high-sensitivity 61F-HSL Supply voltage 100, 200, or 220 VAC; 50/60 Hz 24, 100, 110, 200, or 220 VAC; 50/60 Hz Operating voltage range 85% to 1...
https://www.ia.omron.com/products/family/247/specification.html
...ications Dimensions Catalog last update: July 3, 2023 Ratings Supply voltage 100, 110, 200, 220 VAC; 50/60 Hz Operating voltage range 85% to 110% of rated voltage Power consumption 3 VA Conta...
https://www.ia.omron.com/products/family/249/specification.html
...upply voltage Dimensions Commu- nications Protocol KM50-C1-FLK Single-phase, 2-wire: 100 to 240 VAC Single-phase, 3-wire: 100/200 VAC Three-phase, 3-wire: 100 to 240 VAC Sha...
...upply voltage Dimensions Commu- nications Protocol KM50-E1-FLK Single-phase, 2-wire: 100 to 480 VAC Single-phase, 3-wire: 100/200 VAC Three-phase, 3-wire: 100 to 480 VAC Thr...
...e Must- release voltage G3RZ- 201SLN 5 VDC 4 to 6 VDC 400 Ω ±20% 4 VDC max. 1 VDC min. 5 to 240 VAC 5 to 100 VDC 3 to 264 VAC 3 to 125 VDC 100 μA to 1.0 A 10 A (10 ms) 12 VDC 9.6 to ...
https://www.ia.omron.com/products/family/2809/specification.html
... M Ω min. (at 500 VDC) Contact resistance 15 m Ω max. (initial value) Dielectric strength 1,500 VAC, 50/60 Hz for 1 min between terminals of the same polarity, between current-carrying metal ...
https://www.ia.omron.com/products/family/291/specification.html
...ductive load (A) Resistive load Lamp load Inductive load Motor load NC NO NC NO NC NO NC NO 125 VAC 250 VAC 10 10 2 1.5 1 0.7 6 4 3 2 1.5 1 8 VDC 14 VDC 30 VDC 125 VAC 250 V...
https://www.ia.omron.com/products/family/292/specification.html
...ductive load (A) Resistive load Lamp load Inductive load Motor load NC NO NC NO NC NO NC NO 125 VAC 250 VAC 1 1 0.9 0.45 0.45 0.3 1 1 1.5 0.45 0.75 0.3 8 VDC 14 VDC 30 VDC 125 VDC 1 ...
https://www.ia.omron.com/products/family/293/specification.html
...Unit GX-OC1601 only> 100 m/s 2 (3 times each in 6 directions on 3 axes) Dielectric strength 600 VAC (between isolated circuits) Isolation resistance 20 MΩ or more (between isolated circuits)...
https://www.ia.omron.com/products/family/2953/specification.html
...update: August 1, 2013 Supply voltage Control output Eight-mode Timer Four-mode Timer 24 to 240 VAC/DC Contact output, DPDT (time-limit DPDT, or time-limit SPDT + instantaneous SPDT) Changed ...
...rating modes Supply voltage Control output H3DK-F Flicker OFF start/ flicker ON start 24 to 240 VAC/DC Contact output: SPDT Model H3DK-F 12 VDC Contact output: SPDT Model H3DK-FA Accessories ...
...: July 31, 2013 Operating modes Supply voltage Control output H3DK-G Star-delta Timer 24 to 240 VAC/DC Contact outputs Delta circuit: SPDT, Star circuit: SPDT Model H3DK-G 12 VDC Model H3DK-G...
...Series (time range: 0.1 to 12 s) L Series (time range: 1.0 to 120 s) Power OFF Delay 100 to 120 VAC Contact output: SPDT Model H3DK-HCS H3DK-HCL 200 to 240 VAC Contact output: SPDT M...