| IAグローバル検索 |
...pecifications Dimensions Catalog last update: April 3, 2017 Rated current 1 A Rated voltage 250 V Contact resistance 20 mΩ max. (at 20 mV, 100 mA max.) * Insulation resistance 1,000 MΩ min. (...
https://www.ia.omron.com/products/family/3654/specification.html
... power supply voltage: 30 VDC max., Load current: 100 mA max. Residual voltage: NPN output: 1.2 V max., PNP output: 2 V max. Open collector output (NPN/PNP depending on model) Light-...
https://www.ia.omron.com/products/family/415/specification.html
... output Load power supply voltage: 26.4 VDC max., Load current: 100 mA max. (residual voltage 1 V max.), Open collector output (NPN or PNP depending on model) Light-ON/Dark-ON switch selectab...
https://www.ia.omron.com/products/family/420/specification.html
...NPN open collector: 5 to 24 VDC, 100 mA max. 100 mA load current with a residual voltage of 0.8 V max. 40 mA load current with a residual voltage of 0.4 V max. OFF current (leakage c...
https://www.ia.omron.com/products/family/435/specification.html
... Models: 5 to 100 mA E/FModels: 200 mA max. Y Models: 5 to 300 mA Residual voltage E/FModels: 2 V max. (Load current: 200 mA, Cable length: 2 m) Y Models: Refer to Engineering Data on Data Sh...
https://www.ia.omron.com/products/family/456/specification.html
...oad current 5 to 100 mA NPN open-collector output, 100 mA max. (30 VDC max.) Residual voltage 3 V max. (Load current: 100 mA, Cable length: 2 m) 1 V max. (Load current: 100 mA, Cable...
https://www.ia.omron.com/products/family/467/specification.html
...rol output Load current NPN open-collector output, 100 mA max. (30 VDC max.) Residual voltage 1 V max. Indicators Operation indicator (orange) Power indicator (green) Number of turns of sensi...
https://www.ia.omron.com/products/family/473/specification.html
...10% max. Current consumption 15 mA max. Control output Load current 100 mA Residual voltage 1.5 V max. (Load current: 100 mA, Cable length: 2 m) Indicators Detection indicator (red) Operation...
https://www.ia.omron.com/products/family/474/specification.html
... max. Current consumption 12 mA max. Control output Load current 100 mA max. Residual voltage 1 V max. (Load current: 100 mA, Cable length: 2 m) Sensing liquid position Indented mark position...
https://www.ia.omron.com/products/family/475/specification.html
...5 K3GN-NDC-FLK 24 VDC DC current (0 to 20 mA, 4 to 20 mA) K3GN-NDC-L1 24 VDC DC voltage (0 to 5 V, 1 to 5 V, 0 to 10 V) K3GN-NDC-L2 24 VDC 2 relay contact outputs (SPST-NO) ...
...tion 30 mA max. Control output NPN open collector 26.4 VDC max. 100 mA max. Residual voltage: 1 V max. Operation mode Light-ON/Dark-ON selectable Protective circuit Output short-circuit prote...
...tion 30 mA max. Control output NPN open collector 26.4 VDC max. 100 mA max. Residual voltage: 1 V max. Operation mode Light-ON/Dark-ON selectable Protective circuit Output short-circuit prote...
...tion 30 mA max. Control output PNP open collector 26.4 VDC max. 100 mA max. Residual voltage: 1 V max. Operation mode Light-ON/Dark-ON selectable Protective circuit Output short-circuit prote...
...tion 40 mA max. Control output PNP open collector 26.4 VDC max. 100 mA max. Residual voltage: 1 V max. Operation mode Light-ON/Dark-ON selectable Protective circuit Output short-circuit prote...
... range from 200 W to 3 kW • 20 bit high resolution encoder • 350% momentary maximum torque (200 V, 750 W max.) • Battery-free absolute multi-turn encoder • Safety over EtherCAT (FSoE) High ad...
...atic equipment and separators. There are 1 products of Load Cell Input. Weighing Indicator K3HB-V An Ideal Indicator for OK/NG Judgements in Automated and Picking Machines, Measuring Factors ...
...型放大器內建型光電感測器 E3Z 光電感測器的標準, 年度銷售高達百萬台,令人放心 全彩標記檢測、小型光電感測器 E3ZM-V 業界最小的全彩標記感測器 具耐油性及耐用性的小型光電感測器 E3ZM-C 適合汽車、工...
https://www.omron.com.tw/products/category/sensors/photoelectric-sensors/built-in-amplifier/
...機種。 • 以φ16mm的精巧外觀搭配單純機構,凝聚高度耐振性。 更新日期 2018年12月26日 感測器 影像感測器 鏡頭 3Z4S-LE SV-V Series 3Z4S-LE SV-H / VS-H1 Series 3Z4S-LE VS-LLD Series 3Z4S-LE VS-L / M4...
...e from dust. • Available for lenses for C-mount cameras. 更新日期 2015年6月4日 感測器 影像感測器 鏡頭 3Z4S-LE SV-V Series 3Z4S-LE SV-H / VS-H1 Series 3Z4S-LE VS-LLD Series 3Z4S-LE VS-L / M42-...
...gn but minimized decrease in distortion and brightness. 更新日期 2014年5月21日 感測器 影像感測器 鏡頭 3Z4S-LE SV-V Series 3Z4S-LE SV-H / VS-H1 Series 3Z4S-LE VS-LLD Series 3Z4S-LE VS-L / M42-...