| IAグローバル検索 |
...r: Pt100 or JPt100 Analog input Current input: 4 to 20 mA or 0 to 20 mA Voltage input: 1 to 5 V, 0 to 5 V, or 0 to 10 V Input impedance Current input: 150 Ω max., Voltag...
https://www.ia.omron.com/products/family/3937/specification.html
...r: Pt100 or JPt100 Analog input Current input: 4 to 20 mA or 0 to 20 mA Voltage input: 1 to 5 V, 0 to 5 V, or 0 to 10 V Input impedance Current input: 150 Ω max., Voltag...
https://www.ia.omron.com/products/family/3938/specification.html
...to 20 mA IO-Link K3CV-1ADIA-IL3 Analog current 0 to 20 mA K3CV-1ADIB-IL3 Analog voltage 0 to 10 V K3CV-1ADVA-IL3 Analog voltage -10 to 10 V K3CV-1ADVB-IL3 Thermocouples K Thermocoupl...
...on range -1.00 to 21.00 mA Input resistance 150 Ω or lower K3CV-1ADVA-IL3 Specification 0 to 10 V Instruction range -1.00 to 11.00 V Input resistance 1 MΩ or higher K3CV-1ADVB-IL3 Sp...
https://www.ia.omron.com/products/family/3947/specification.html
...S image elements 1/2.9-inch equivalent Color/Monochrome Color Effective pixels 1440 (H) × 1080 (V) Pixel size 3.45 × 3.45 um Shutter system Global Shutter Frame rate (image acquisition time) ...
https://www.ia.omron.com/products/family/3949/specification.html
... Load power supply voltage: 26.4 VDC max. Class 2 Load current: 50 mA max. (residual voltage: 2 V max. for load current of 10 to 50 mA, 1 V max. for load current of less than 10 mA),...
https://www.ia.omron.com/products/family/3954/specification.html
...ent: EN61010-1/EN61010-2-030, Pollution Degree 2, Overvoltage/measurement Category II (L-N: 480 V), III (L-N: 300 V) EMC: EN61326-1, ClassA (EMI), Industrial Location (EMS) UL •UL610...
https://www.ia.omron.com/products/family/3955/specification.html
... output current (per branch) 3.8 A Total output current 10 A Voltage variable range *4 24 to 28 V (adjustable with V.ADJ) Ripple noise voltage (at rated input and outputs) *1 80 mV m...
https://www.ia.omron.com/products/family/3956/specification.html
...IP • Output voltage: 24 VDC • Compact S8VK-S[][][]24 • Output voltage: 24 VDC • Three-phase 200-V Power Supplies S8VK-WA[][][]24 UPS Output voltage during backup operation: 24 VDC±5% Revision...
...put terminal: 6 Output signal External output terminal: 6 Counter input format Voltage input (5 V, 24 V) Pulse Input Method In 2ch Mode: Phase differential pulse (multiplication x1/2...
https://www.ia.omron.com/products/family/3961/specification.html
...l output Load power supply voltage: 30 VDC max., Load current: 100 mA max. (residual voltage: 1 V max.) Open-collector output (NPN or PNP depending on model), Light-ON/Dark-ON selectable Self...
https://www.ia.omron.com/products/family/410/specification.html
...when the L terminal and positive (+) terminal are connected. Do not connect the L terminal to 0 V when using dark-ON operation. When using light-ON, it is useful to select the connector EE-10...
...NPN open collector: 5 to 24 VDC, 100 mA max. 100 mA load current with a residual voltage of 0.8 V max. 40 mA load current with a residual voltage of 0.4 V max. OFF current (leakage c...
https://www.ia.omron.com/products/family/436/specification.html
...x. Leakage current 0.8 mA max. Control output Switching capacity 3 to 100 mA Residual voltage 3 V max. (Load current: 100 mA, Cable length: 2 m) Indicators D1 Models: Operation indicator (red...
https://www.ia.omron.com/products/family/451/specification.html
...% max. Leakage current 0.8 mA max. Control output Load current 3 to 100 mA Residual voltage 3.3 V max. (under load current of 100 mA with cable length of 2 m) Indicators D1 Models: Operation ...
https://www.ia.omron.com/products/family/460/specification.html
...% max. Leakage current 0.8 mA max. Control output Load current 3 to 100 mA Residual voltage 3.3 V max. (Load current: 100 mA, Cable length: 2 m) Indicators D1 Models: Operation indicator (red...
https://www.ia.omron.com/products/family/462/specification.html
...puts Solid- state NPN Load resistance: 4.7 kΩ, 100 mA max. (30 VDC max.) (Residual voltage: 1.5 V max.) PNP Load resistance: 4.7 kΩ, 100 mA max. (30 VDC max.) (Residual voltage: 1.5 ...
https://www.ia.omron.com/products/family/464/specification.html
...: February 18, 2013 Model E6A2-CWZ3E E6A2-CWZ3C E6A2-CWZ5C Power supply voltage 5 VDC -5% to 12 V +10%, ripple (p-p): 5% max. 12 VDC -10% to 24 VDC +15%, ripple (p-p): 5% max. Current consump...
https://www.ia.omron.com/products/family/486/specification.html
...put Output capacity Applied voltage: 30 VDC max. Sink current: 35 mA max. Residual voltage: 0.4 V max. (at sink current of 35 mA) Source current: 35 mA max. Residual voltage: 0.4 V m...
https://www.ia.omron.com/products/family/496/specification.html
...ransistor output (with sinking current of 18 mA min.) or contact output Input signals ON 0 to 4 V (5 mA min.) OFF 8 to 12 V (2 mA max.) Short-circuit current 11 mA TYP (18 mA max.) M...
https://www.ia.omron.com/products/family/571/specification.html