faq03126

...separate motor and clutch connection. STP socket wiring and H2C-F top wiring are irrelevant and so a large change in wiring is required. The mounting method also must change from STP sockets ...

https://www.ia.omron.com/support/faq/answer/19/faq03126/

faq03173

...nt of the external connection is not compatible. H3AM-NS cannot be used with DC power supplies, so see whether H3CR-A8E can be used to create a substitute function. The size of the panel cuto...

https://www.ia.omron.com/support/faq/answer/19/faq03173/

faq01858

... - 100.8 W = 25.2 W To convert the internal loss to calories: By Joule's law, 1 W = 0.24 cal/s, so 25.2 W = 25.2 × 0.24 cal/s = 6.05 cal/s S8VS Multi-Function Indication Monitor for Productio...

https://www.ia.omron.com/support/faq/answer/22/faq01858/

faq01877

...one that is one step higher in capacity. The connected load exceeds the Power Supply's ratings, so it is triggering the overload protection function. Select a different Power Supply with suff...

https://www.ia.omron.com/support/faq/answer/22/faq01877/

faq01991

...e expectancy was calculated by high-temperature testing of the aluminum electrolytic capacitor, so these values are guidelines only. With S8VS Series Switch Mode Power Supply, the Maintenance...

https://www.ia.omron.com/support/faq/answer/22/faq01991/

faq01993

...herwise inoperative. Use identical models for Power Supplies A and B. Select the Power Supplies so that either one can supply the required load capacity. When connecting Power Supplies for ba...

https://www.ia.omron.com/support/faq/answer/22/faq01993/

faq02011

...result in an unbalanced load current, possibly causing the rated output current to be exceeded, so the parallel connection is not possible. Use the same length and thickness of load connectio...

https://www.ia.omron.com/support/faq/answer/22/faq02011/

FAQ01127 for Photomicro Sensors | OMRON Industrial...

...g Load Resistance Values Example description and cause: The load resistance value is too small, so the phototransistor cannot pass the circuit current. (Optical current IL ...

https://www.ia.omron.com/support/faq/answer/24/faq01127/

FAQ01133 for Photomicro Sensors | OMRON Industrial...

...turer responsibility for any resulting deterioration or damage. Be careful to design the system so that operation will be performed within these ratings. In actual operation, derating is used...

https://www.ia.omron.com/support/faq/answer/24/faq01133/

FAQ01138 for Photomicro Sensors | OMRON Industrial...

... leakage of the phototransistor when a specified bias voltage is imposed on the phototransistor so that the polarity of the collector is positive and that of the emitter is negative on condit...

https://www.ia.omron.com/support/faq/answer/24/faq01138/

faq02681

...ight). A circuit to fully stabilize the power supply voltage is not built into the Sensors, and so the voltage supplied to the Sensors will fall when the LED is lit due to the cable resistanc...

https://www.ia.omron.com/support/faq/answer/24/faq02681/

faq02687

...the negative terminal will not result in failure or other problems, but the product is designed so that the L terminal is open or connected to the positive terminal, so leave it open...

https://www.ia.omron.com/support/faq/answer/24/faq02687/

faq00060

.../CJ-series Programmable Controllers are OFF. Other CPU Unit models do not have switch settings, so this does not need to be checked. When There Is a Power Supply Failure Check the power suppl...

https://www.ia.omron.com/support/faq/answer/26/faq00060/

faq00069

...Answer  No, the peripheral port on the CPU Unit of Programmable Controllers do not supply 5 V, so the NT-AL001-E cannot be connected. Use an RS-232C port. CJ2 Introducing the Flagship CJ2 CP...

https://www.ia.omron.com/support/faq/answer/26/faq00069/

faq00077

...e memory areas. However, the device type is set to CQM1 when using the SYSMAC Support Software, so the check for the usable memory areas, which is normally performed when using CPM2C, will no...

https://www.ia.omron.com/support/faq/answer/26/faq00077/

faq00154

...Link Unit? Answer  Yes. The 3G2A5-LK201-EV1 cannot be used together with the SYSMAC LINK Unit, so switch to the C500-LK203. CJ2 Introducing the Flagship CJ2 CPU Units, with Built-in Multifun...

https://www.ia.omron.com/support/faq/answer/26/faq00154/

faq00279

... containing the clock data for programming. The words used for click data depends on the model, so refer to the operation manual. CJ2 Introducing the Flagship CJ2 CPU Units, with Built-in Mul...

https://www.ia.omron.com/support/faq/answer/26/faq00279/

FAQ00287 for Programmable Controllers | OMRON Indu...

...he Programmable Controller's power supply does not go OFF. The battery service life is 5 years, so replace the battery every 5 years to prevent problems such as electrolyte leakage. CJ2 Intro...

https://www.ia.omron.com/support/faq/answer/26/faq00287/

faq00454

... Negative logic (see note) is much more common among Output Units for Programmable Controllers, so we recommend using models with negative logic. Note:C200H Programmable Controllers Output Un...

https://www.ia.omron.com/support/faq/answer/26/faq00454/

faq00923

... CIO 0. 2.The 8 bits extracted in the previous step must be moved to the lower 8 bits of a word so that they can be used in processing in the next program rung. Use the MOVE DIGITS instructio...

https://www.ia.omron.com/support/faq/answer/26/faq00923/